background image

6 

 

 

 

 

STEP 3 : Learning the Sirens

 

 

Up to 8 Siren units can be activated by single Transceiver.   In BUS Mode, these Sirens can be 
divided to two groups (A&B) for activating their Sirens (by receiving two separate activation 
controls). 

 

 

 

 

Instruction

 

Description

 

 

1

 

Place the Siren Units on a flat 
surface

 

To verify back tamper is closed.

 

2

 

Connect Piezo Siren cable

 

 

 

3

 

Connect battery cable

 

The Siren will beep once and then the LED power will 
blink for a period of 30 seconds, please wait to the end 
of the blinking before activating or learning.

 

4

 

Verfiy Siren Tampers are open

 

Siren tampers must be open during the learning mode

 

 

5

 

Set Jumpers B and C according 
to Table 1

 

Low Battery indication's beeps and flashes will be "on" 
no matter what the status of Mode Jumpers B and C.

 

 

6

 

Transceiver 

 

<Learn/Test>

 

On the Transceiver press' Learn/Test button. 
Green and RED  LED on Transceiver starts flashing.

 

 

7

 

Siren 

 

<Learn>

 

On the Siren press Learn button. Green LED on the 
Transceiver turns to solid "ON" for 1 to 3 seconds and 
then turns OFF.  The Siren is learned by the Transceiver.

 

8

 

Close the Siren tampers

 

 

 

Function Testing after learning.

 

 

After the learning completed and before the installation verify that the Siren Units 
are functioning as defined. 

 

   

Perform Arm/Disarm verify beep/flash indications. 

   

Perform an Alarm; verify Piezo and Flash are activated. 

   

Perform Alarm Reset via the Keypad by User pin code. 

Summary of Contents for 2W-SIROUT-S

Page 1: ...i 2W SIROUT S Two Way Outdoor Sounder With Battery INSTALLATION MANUAL P N 7106663 Rev A...

Page 2: ...NG THE SIRENS 6 FUNCTION TESTING AFTER LEARNING 6 SETTING THE 2W SIROUT S FOR SERENITY CONFIGURATION 7 SETTING THE 2W SIROUT S CONFIGURATION 7 LEARN THE 2W SIROUT S WITH SERENITY C P 8 FUNCTION TESTIN...

Page 3: ...X PB S installed in the SIM The 2W SIROUT S unit can be powered by Lithium Battery 3 6V 14Ah or by external power supply 12V 0 8A or both SIM TX RX PB S Introduction into the SIM Panel SIM TX RX PB S...

Page 4: ...s cable while pressing and holding the reset button Continue to hold the reset button for several seconds till led s will finish to flash red green alternately Wait until the led s stops flashing and...

Page 5: ...guration Mode Figure 2 Siren Description Diagram The Siren unit can be powered by Lithium Battery 3 6V 14Ah or by external power supply 12V 0 8A or both in case of both the battery use as backup NOTE...

Page 6: ...ep LOW BAT 2 Beeps D 2 Min Time out 15 Min Time out Table 1 Jumpers Set Up Note On control panel must disable Arm Disarm chirps from Output 1 for area A and area B if system is partitioned P50E1E Turn...

Page 7: ...during the learning mode 5 Set Jumpers B and C according to Table 1 Low Battery indication s beeps and flashes will be on no matter what the status of Mode Jumpers B and C 6 Transceiver Learn Test On...

Page 8: ...w See Figure 6 and open the cover 3 Place the unit on the installation surface and mark out the four screw holes 4 Use a 6 mm bit to drill the holes Figure 5 Transceiver Unit Figure 6 Transceiver Inst...

Page 9: ...ation of each Siren units Make sure that there is Radio coverage to this location from the Transceiver Place the Siren Units high enough off the ground in order to make them inaccessible to passers by...

Page 10: ...at the Piezo Siren is connected to the Piezo connector as shown below Figure 5 Siren Connectors 8 Insert the battery into the battery clip and connect it to the BAT connector shown above Note The batt...

Page 11: ...battery shall be Installed replaced by service man The Siren will beep once and then the LED power will blink for a period of 30 seconds please wait to the end of the blinking before activating or lea...

Page 12: ...2 min 15 min According the status of Jumper D Low Battery Level 2 8V Low Battery Indication LED Flash Arm Disarm According the status of Jumper B C Arm Disarm Indication LED Flash Arm 1 Disarm 3 LED...

Page 13: ...IN 1 Trigger Alarm IN 2 Trigger Key Arm Disarm BUS Connection via Fast Connection or Terminals Outputs Tamper Out Terminals Dry contacts 12V DC 100mA Indication Blue LED indicate Rx TX Tamper Connect...

Page 14: ...18 www sim security net...