6
STEP 3 : Learning the Sirens
Up to 8 Siren units can be activated by single Transceiver. In BUS Mode, these Sirens can be
divided to two groups (A&B) for activating their Sirens (by receiving two separate activation
controls).
Instruction
Description
1
Place the Siren Units on a flat
surface
To verify back tamper is closed.
2
Connect Piezo Siren cable
3
Connect battery cable
The Siren will beep once and then the LED power will
blink for a period of 30 seconds, please wait to the end
of the blinking before activating or learning.
4
Verfiy Siren Tampers are open
Siren tampers must be open during the learning mode
5
Set Jumpers B and C according
to Table 1
Low Battery indication's beeps and flashes will be "on"
no matter what the status of Mode Jumpers B and C.
6
Transceiver
<Learn/Test>
On the Transceiver press' Learn/Test button.
Green and RED LED on Transceiver starts flashing.
7
Siren
<Learn>
On the Siren press Learn button. Green LED on the
Transceiver turns to solid "ON" for 1 to 3 seconds and
then turns OFF. The Siren is learned by the Transceiver.
8
Close the Siren tampers
Function Testing after learning.
After the learning completed and before the installation verify that the Siren Units
are functioning as defined.
Perform Arm/Disarm verify beep/flash indications.
Perform an Alarm; verify Piezo and Flash are activated.
Perform Alarm Reset via the Keypad by User pin code.