5
Siren's Jumper's MODE SET-UP
Jumper No.
Function if = O (Open)
Function if =1 (Close)
A
Not in used for RUNNER 2 and
SERENITY control panels
B
NO Flashes with ARM/Disarm
Flashes appear with ARM/Disarm
Arm: 2 Flashes (@LOW BAT 3+3
Flashes)
Disarm: 1 Flash (@LOW BAT 2
Flashes)
C
NO Beeps with ARM/Disarm
Beeps sound with ARM/Disarm
Arm: 2 Beeps(@LOW BAT 3+3
Beeps)
Disarm: 1 Beep (@LOW BAT 2
Beeps)
D
2 Min Time out
15 Min Time out
Table 1 - Jumpers Set-Up
Note:
On control panel must disable Arm/Disarm chirps from Output‐1 for area A
and area B if system is partitioned
P50E1E: Turn off option 1.
P52EE1E: Turn off option 1.
Mnemonic
Description
<PROG>
PROGRAM key.
<ENTER>
Enter key.
Press key or enter parameter
Notes:
The learning between the Transceiver to the Siren Units should be performing
before the installation of the Siren Units.
It's recommended to locate the Siren at least 2 meter distance from the
transceiver during the learning mode.