Balanc�ng data (For �nstallat�on)
50 Pa
100 Pa
Ground vent�lat�on
20 l/s (72 m3/h)
20 l/s (72 m3/h)
Pressure
60 Pa
120 Pa
Damper pos�t�on
G 6
G 4.3
Sound pressure
(Lpa)
25 dBA
30 dBA
Forced vent�lat�on:
40 l/s (144 m3/h)
40 l/s (144 m3/h)
Pressure
50 Pa
100 Pa
Damper pos�t�on
F 5
F 3.3
Sound pressure
(Lpa)
25 dBA
32 dBA
The product factory sett�ngs are based on 50 pA
Depend�ng on the pressure be�ng measured, the tables must be
used to f�nd the po�nts to wh�ch the a�r flow �s adjusted. For bas�c
suct�on, use; (/ for forced suct�on, use;).
For balanc�ng, the Balanc�ng d�agram and data
are used:
Adjustment of a�r flow
24.07.2020
18