8
│
GB
│
IE
SMS 300 B2
Safety switches
The appliance has two safety switches
0
on the left and right
of the underside
of the appliance. The UV-C lamp
8
only switches on when the vibration button
w
is pressed if both safety switches
0
are pressed simultaneously. This deactivates
the automatic switch-off of the UV-C lamp
8
. This happens automatically when
the switched-on appliance is placed on a level surface (fig. A).
A
UV-C lamp on
If the safety switches lose contact with the substrate, the automatic switch-off
function is activated and the UV-C lamp
8
stops lighting (figs. B and C).
B
UV-C lamp off
C
UV-C lamp off
Operation
WARNING! RISK OF INJURY!
►
Never look into the UV-C lamp
8
during use!
►
Never use the appliance on people or animals! UV radiation can lead to
injuries to eyes and skin.
►
Only operate the appliance when it has been properly assembled.
This is the only way to avoid the dangers of UV radiation.
►
Use this appliance only as described in these operating instructions.
This is the only way to avoid the dangers of UV radiation.
NOTE
►
Use the appliance only if it is completely and correctly assembled. The dust
container
3
and the HEPA dust filter
4
must be inserted correctly and
undamaged. If dirt gets into the motor of the unit, it could cause motor damage.
►
Make sure that the safety switches of the UV-C lamp
8
on the underside
of the appliance are not blocked.
►
Test the appliance on a small, unobtrusive spot first.