background image

GENERAL 

The Silvan Utepak, Trukpak and Squatpak are portable sprayer’s. 
Whether you are a commercial grower, or a home gardener you will find many uses for this unit.  The tank pump and wand fittings 
are corrosion resistant and are suitable for applying weedicides, herbicides, insecticides, fungicides, miticides, organic and green 
formulations. 
A variety of models are available configured with different tank capacities, pumps and sprayguns all suited for spot spraying but 
may be used in conjunction with a boom for boom spraying. Some models also include additional features such as hose reels, 
regulators or included boomless nozzles. 
 
Your Product code indicates the configuration detailing the tank style, tank capacity, pump type and if a hose reel is fitted,  

                                       for example.  

SQ400-S8-1 

Other product features may vary that are not covered in the product code suck as the filtration, spraygun used and if a regulator is 
fitted. 

 
PUMP

 (The fitted pump is dependent which model spray unit was purchased and is indicated by the product code as described 

above). 

 

361-8000

 Shurflo pump, 12 volt DC electric, max current 7.3 amps, 6.8 litres/minute open flow, Max 60psi on demand electric 

pressure switch, On/Off switch.  

 

 

361-2088

 Shurflo, 12 volt DC electric, max current 8 amps, 11.3 litres/minute open flow, Max 45psi on demand electric 

pressure switch, On/Off switch.  

 

 

DDP-552A

 Aquatec Smoothflo, 12 volt DC electric, max current 9 amps,  7 litres/minute open flow, Max 120psi on demand 

electric pressure switch, On/Off switch. Special Feature includes adaptive pressure sensing technology to auto bypass flow to 
prevent pressure spikes while maintaining higher pressures and flows 

 

DDP-550

 Aquatech High Capacity, 12 volt DC electric, max current 18 amps,  20 litres/minute open flow, Max 60psi on 

demand electric pressure switch, On/Off switch. 

 

DDP-554

 Aquatec High Pressure Smoothflo, 12 volt DC electric, max current 16 amps,  5 litres/minute open flow, Max 200psi 

on demand electric pressure switch, On/Off switch. Special Feature includes adaptive pressure sensing technology to auto 
bypass flow to prevent pressure spikes while maintaining higher pressures and flows 

 

DDP-555 

Aquatec Medium Capacity, 12 volt DC electric, 12 litres/minute open flow, Max 45psi on demand electric pressure 

switch, On/Off switch. 

 

HOSE 

 

6 metres of 10mm I.D delivery hose standard (applicable for models that do not include hose reels) 

 

TANK 

100, 200, 300 and 400 litre moulded translucent tank with calibrated litre graduations.  Material is U.V. stabilized and impact 
resistant polyethylene with screw on lid has anti-spill breather.  
100L Utepak and 200L Trukpak feature inmoulded inserts in the tank base allowing the tank to be bolted down to a tray or skid 
300L and 400L Squatpak tank feature a large internal baffle for reduction of fluid surge in transit to help improve handling, the 
tank tops feature deep grooves for tie-downs and 2 accessory mounting points (only 1 available when hose reel is fitted)  
 

FILTRATION 

In line suction filter fitted to pump and basket strainer beneath the tank lid to eliminate coarse debris .  
 

Squatpak style tank, 400L capacity fitted with 
DDP-550 pump and 30m Eco Hosereel

Specifications 

Tank Style 

UP

 Utepak 

TK

 Trukpak 

SQ

 Squatpak 

Tank Capacity 
 (Liters) 

100

 

 

200

 

 

300

 

 

400

 

 

Pump Type 

S1

 361-8000 

S3

  

361-2088 

S7

  

DDP-552A

 

S8

  

DDP-550

 

S9

 DDP-554 

S10 

DDP-555

 

Hose  Reel 

-1

 

30m Eco Reel (manual action) 

-2

 

15m Spring Retractable reel 

 

 

 

Summary of Contents for Squatpak 300L

Page 1: ...Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 Utepak 100L Trukpak 200L Squatpak 300L Squatpak 400L ...

Page 2: ...not cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services as specified in the Owner Operator Manual applicable to the product Damage caused by continued use of a product after initial failure Any product which has been repaired by o...

Page 3: ...ng and safety instructions Warning Refer to the chemical manufacturer s label for correct use and safe handling instructions of chemicals before use Warning Never allow inadequately trained personnel to attach or operate the implement Warning Before carrying out maintenance work wash the sprayer thoroughly to remove all toxic chemicals that may contaminate the sprayer Warning Do not point spray gu...

Page 4: ...ssure spikes while maintaining higher pressures and flows DDP 550 Aquatech High Capacity 12 volt DC electric max current 18 amps 20 litres minute open flow Max 60psi on demand electric pressure switch On Off switch DDP 554 Aquatec High Pressure Smoothflo 12 volt DC electric max current 16 amps 5 litres minute open flow Max 200psi on demand electric pressure switch On Off switch Special Feature inc...

Page 5: ...allows the pump to be shut down when the tank is empty preventing overheating and damage to the pump Important Note Ensure that distance from the power supply to pump is minimised Important Note If extending power cables ensure a cable of equal or preferably greater current capacity is used as over extended wires may overheat blow fuses or damage the pump Important Note Consult your vehicle instru...

Page 6: ...OSE ANCHOR We have supplied a Plastic Hose Tie to protect the pump housing or hose fitting from possible damage caused when the hose is pulled tight or over stretched The hose can be tied against the switch bracket as shown in the diagram below do not over tighten or kink the hose as this may restrict the flow Maintenance Dispose of unused chemical and water used for rinsing in a manner that will ...

Page 7: ... nuts 3 Fit Hose reel to the upright bracket using 2x M8X25mm Bolts Washer nyloc nuts 4 Loop the inlet hose under the reel and cut hose to suitable length to meet the pumps inlet allow length for the hose to swivel Fit elbow hosetail and hose clamp then fit to pump 4 1 2 3 15m Reel 200L 1 Fit the 2 x long brackets to the tank with 4x M8x16mm Bolts Washer Spring Washers 2 Fit the upright bracket as...

Page 8: ...E 244 264 Greens Rd Dandenong South 3175 Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 ...

Reviews: