Special Installation. Hose Reel kit fitment for 

Fitting the Spray Gun 

Different model sprayers feature different 
spray guns and have different inlets 
 

Method 1.

 Fit direct to hose. 

The PA spray gun can  
be directly fitted to the 
¼” Fitting on the hose 
reel  
(Requires old existing 
 fitting to be removed). 

1. 

1. Fit the 2 x long brackets to the 
tank with 4x M8x16mm Bolts, 
Washer & Spring Washers 

2. Fit the hose reel with the 4x M10 
nuts Bolts, Washer & Spring Washers 
 
 
3. Loop the Hosereel inlet hose under 
as shown and cut to meet the pumps 
inlet. Fit the elbow hosetail and hose 
clamp then fit to the pump 

 

30m Eco Reel 

2. 

3. 

15m Reel (100L) 

1. Fit the 1 x long and 1x angle bracket 

to the tank with 3x M8x16mm Bolts, 
Washer & Spring Washers 

 
2. Fit the upright bracket as shown with 

2x M8X25mm Bolts, Washer & nyloc 
nuts 
 

3. Fit Hose reel to the upright bracket 

using 2x M8X25mm Bolts, Washer & 
nyloc nuts. 

 
4. Loop the inlet hose under the reel 
and cut hose to suitable length to 
meet the pumps inlet (allow length for 
the hose to swivel). Fit elbow hosetail 
and hose clamp then fit to pump 
 

4. 

1

.

 

2. 

3. 

15m Reel (200L) 

1. Fit the 2 x long brackets to the tank 

with 4x M8x16mm Bolts, Washer & 
Spring Washers 

 
2. Fit the upright bracket as shown with 

2x M8X25mm Bolts, Washer & nyloc 
nuts 
 

3. Fit Hose reel to the upright bracket 

using 2x M8X25mm Bolts, Washer & 
nyloc nuts. 

 
4. Loop the inlet hose under the reel 
and cut hose to suitable length to 
meet the pumps inlet (allow length for 
the hose to swivel). Fit elbow hosetail 
and hose clamp then fit to pump 
 

4.

1.

2.

3.

Method 2.

 Cut the hose. 

The Triam and Spotjet spraygun both have 
½” Connections which do not directly fit to 
the hose reels ¼” fitting.  
Remove any existing hose connections to 
the spraygun. Cut the swaged fitting from the 
hose reel then fit spraygun using the 
included hosetail. 

Summary of Contents for Squatpak 300L

Page 1: ...Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 Utepak 100L Trukpak 200L Squatpak 300L Squatpak 400L ...

Page 2: ...not cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services as specified in the Owner Operator Manual applicable to the product Damage caused by continued use of a product after initial failure Any product which has been repaired by o...

Page 3: ...ng and safety instructions Warning Refer to the chemical manufacturer s label for correct use and safe handling instructions of chemicals before use Warning Never allow inadequately trained personnel to attach or operate the implement Warning Before carrying out maintenance work wash the sprayer thoroughly to remove all toxic chemicals that may contaminate the sprayer Warning Do not point spray gu...

Page 4: ...ssure spikes while maintaining higher pressures and flows DDP 550 Aquatech High Capacity 12 volt DC electric max current 18 amps 20 litres minute open flow Max 60psi on demand electric pressure switch On Off switch DDP 554 Aquatec High Pressure Smoothflo 12 volt DC electric max current 16 amps 5 litres minute open flow Max 200psi on demand electric pressure switch On Off switch Special Feature inc...

Page 5: ...allows the pump to be shut down when the tank is empty preventing overheating and damage to the pump Important Note Ensure that distance from the power supply to pump is minimised Important Note If extending power cables ensure a cable of equal or preferably greater current capacity is used as over extended wires may overheat blow fuses or damage the pump Important Note Consult your vehicle instru...

Page 6: ...OSE ANCHOR We have supplied a Plastic Hose Tie to protect the pump housing or hose fitting from possible damage caused when the hose is pulled tight or over stretched The hose can be tied against the switch bracket as shown in the diagram below do not over tighten or kink the hose as this may restrict the flow Maintenance Dispose of unused chemical and water used for rinsing in a manner that will ...

Page 7: ... nuts 3 Fit Hose reel to the upright bracket using 2x M8X25mm Bolts Washer nyloc nuts 4 Loop the inlet hose under the reel and cut hose to suitable length to meet the pumps inlet allow length for the hose to swivel Fit elbow hosetail and hose clamp then fit to pump 4 1 2 3 15m Reel 200L 1 Fit the 2 x long brackets to the tank with 4x M8x16mm Bolts Washer Spring Washers 2 Fit the upright bracket as...

Page 8: ...E 244 264 Greens Rd Dandenong South 3175 Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 ...

Reviews: