FILLING THE TANK AND ADDING CHEMICAL 
Warning : Before using the sprayer for the first time or adding chemical check the operation and function of the 
sprayer with clean water 

Check that the battery power supply is charged, the filters are clean and all fittings, hoses and gun connections are tight. 
Partly fill the sprayer before adding chemical. Always use clean water to prevent blockages and ensure chemical function is 
not inhibited.  
Connect pump and ensure it primes correctly, holding the spray lance trigger on until it sprays steadily. 
Check all pipes, hoses, hose clamps and connections for leaks or damage. 
Be sure to wear safety equipment as recommended by the chemical manufacturer before adding chemical to the 
sprayer. 
 
Once satisfied that all hoses and connections are working and there is no leaks or damage. 
 
Add the chemical according to the directions on the chemical container following all safety and protective equipment 
recommendations. 
Do not use wet powders or chemicals that must remain suspended in solution and require agitation. Only use chemicals or 
dyes that fully dissolve. 
Do not use a sprayer that has been used to spray herbicides for insecticides or nutrients unless the sprayer has been 
thoroughly cleaned including neutralizing the herbicide according to the manufactured directions if required. 

PUMP HOSE ANCHOR 

 

We have supplied a Plastic Hose Tie to protect the pump housing or 
hose fitting from possible damage caused when the hose is pulled 
tight or over stretched. 

The hose can be tied against the switch 
bracket as shown in the diagram below, 
do not over tighten or kink the hose as 
this may restrict the flow. 

Maintenance 

Dispose of unused chemical and water used for rinsing in a manner that will not endanger 
people animals or the environment. 

After spraying rinse out the spray lines and tank with clean water. To avoid chemical contamination wear appropriate 
protective equipment including gloves whenever maintenance is carried out; turn off the pump and depress the trigger on 
the spray lance to dissipate any pressure. After spraying is completed, drain unused chemicals from the tank. Rinse the 
tank with clean water then operate the sprayer with clean water in the tank to clean out the pump, hose and spray lance. 
Do not leave chemicals in the tank as they may crystallize or form solids and block in pump, spray lines, nozzle or filters. 
A cleaning agent may be required to clean away residues of spray dies or other solutions that leave deposits in the pump 
and lines. 
 
The foot filter should be checked and cleaned if necessary each time the tank is filled.  Appropriate protective equipment 
should be used whenever maintenance is carried out. 
If heavy frosts are experienced, run the pump to make sure pump and spray lines are dry.  This will prevent water freezing 
in the pump or spray lines and damaging sprayer. 
 

Installation 

Summary of Contents for Squatpak 300L

Page 1: ...Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 Utepak 100L Trukpak 200L Squatpak 300L Squatpak 400L ...

Page 2: ...not cover Conditions resulting from misuse use of incompatible chemicals exceeding machine specifications including overloading impact damage negligence accidental damage or failure to perform recommended maintenance services as specified in the Owner Operator Manual applicable to the product Damage caused by continued use of a product after initial failure Any product which has been repaired by o...

Page 3: ...ng and safety instructions Warning Refer to the chemical manufacturer s label for correct use and safe handling instructions of chemicals before use Warning Never allow inadequately trained personnel to attach or operate the implement Warning Before carrying out maintenance work wash the sprayer thoroughly to remove all toxic chemicals that may contaminate the sprayer Warning Do not point spray gu...

Page 4: ...ssure spikes while maintaining higher pressures and flows DDP 550 Aquatech High Capacity 12 volt DC electric max current 18 amps 20 litres minute open flow Max 60psi on demand electric pressure switch On Off switch DDP 554 Aquatec High Pressure Smoothflo 12 volt DC electric max current 16 amps 5 litres minute open flow Max 200psi on demand electric pressure switch On Off switch Special Feature inc...

Page 5: ...allows the pump to be shut down when the tank is empty preventing overheating and damage to the pump Important Note Ensure that distance from the power supply to pump is minimised Important Note If extending power cables ensure a cable of equal or preferably greater current capacity is used as over extended wires may overheat blow fuses or damage the pump Important Note Consult your vehicle instru...

Page 6: ...OSE ANCHOR We have supplied a Plastic Hose Tie to protect the pump housing or hose fitting from possible damage caused when the hose is pulled tight or over stretched The hose can be tied against the switch bracket as shown in the diagram below do not over tighten or kink the hose as this may restrict the flow Maintenance Dispose of unused chemical and water used for rinsing in a manner that will ...

Page 7: ... nuts 3 Fit Hose reel to the upright bracket using 2x M8X25mm Bolts Washer nyloc nuts 4 Loop the inlet hose under the reel and cut hose to suitable length to meet the pumps inlet allow length for the hose to swivel Fit elbow hosetail and hose clamp then fit to pump 4 1 2 3 15m Reel 200L 1 Fit the 2 x long brackets to the tank with 4x M8x16mm Bolts Washer Spring Washers 2 Fit the upright bracket as...

Page 8: ...E 244 264 Greens Rd Dandenong South 3175 Australia Telephone 61 03 9215 2700 Facsimile 61 03 9215 2701 www silvan com au NEW ZEALAND 22 Sunshine Avenue Te Rapa Hamilton 2001 New Zealand Telephone 64 07 8496033 Fax 64 07 8496070 www silvannz co nz SILVAN AUSTRALIA PTY LTD ABN 48 099 851 144 ...

Reviews: