Product dimensions (mm)
Input for power supply
Drill the hole for the cable passage on the base of the Prism, choosing between the
bottom or the bottom, depending on how you want to bring the power supply to the
Prism. Follow the guide point engraved on the Prism casing to drill the hole. For the hole
at the bottom, install a suitable cable gland with a maximum diameter of 32 mm and a
maximum nut size of 36 mm.
The cable glands used must be selected and installed in such a way as to maintain the IP
rating of the enclosure.
Do not drill prisms in places other than those indicated in this manual. Drilling
at points other than those indicated will result in the loss of the warranty.
10
-
Prism SOLAR rel. 2.2.2