Introduction
10
users manual inverter SE2.8i - SE3.8i - SE4i - SE5i
1.3 Adjustable Parameter Settings
This new series of SE inverters have, currently, three models to fulfill the market needs for the countries of Germany, Italy, and Spain. It can
be distinguished by the model names described as followings:
SE xxE: For Germany
SE xxE-IT: For Italy
SE xxE-ES: For Spain
Parameter
Germany
Italy
Spain
Model name
Standard
Over-voltage (VAC)
Under-voltage (VAC)
Over-frequency (Hz)
Under-frequency (Hz)
Over-voltage clearing time (cycle)
Under-voltage clearing time (cycle)
Over-frequency clearing time (cycle)
Under-frequency clearing time (cycle)
Voltage quality monitoring* (VAC)
Voltage quality monitoring time* (s)
Reconnect delay (s)
PV start voltage (VDC)
SE xxE
VDE0126-1-1
260.0
190.0
50.19
47.51
8
8
5
5
253.0
300
20
235.0
SE xxE-IT
DK5940
262.0
188.0
50.3
49.7
4
9
3
3
257.6
0 (NA)
20
235.0
SE xxE-ES
RD1663, RD661
253.0
196.0
51.0
48.0
8
8
5
5
250.7
0 (NA)
180
235.0
* The period of time for the SE inverter to disconnect from the grid and
enter the Monitoring mode after the detection of the AC voltage that is
higher than the
Voltage quality monitoring
setting and below the
Over-
voltage
setting. This function is available only in the models of Germany
type according to the VDE 0126-1-1, Clause 4.2.3.
Summary of Contents for se2.8i
Page 1: ...nverters...
Page 12: ...11 1 pc 1 pc...
Page 18: ...on 17 OFF Fig 2 3 3 Remove the cover of the wiring box...
Page 29: ...Fig 2 3 3 4 RS 485 connection Installation user s manual inverter SE2 8i SE3 8i SE4i SE5i...
Page 54: ...53...
Page 64: ...63 E5i S...
Page 72: ...71 4 2 1 1 Remove the cover of the Inverter 5 4 2 1 2 Remove the DC and AC wires...
Page 76: ...75 tall the cover plate and fix it on the top of the wiring box...
Page 81: ...Notes user s manual inverter SE2 8i SE3 8i SE4i SE5i...
Page 82: ......