Operating voltage
11
The
maximum voltage
of the system is 1000 V in Europe (see module
label) and 600 V in USA (see module label). The maximum number of
modules to be connected in series (in cell temperature conditions of
77ºF / 25°C), is 16 in USA and 24 in Europe
WARNING: the value for the maximum number of modules must be
corrected based their location and in accordance with the correction
parameters provided in the formula, since the voltage increases as
the temperature decreases. Calculate the value based on the lowest
temperature in the region where the modules will be installed.
!
Maximum system voltage
V
oc77°F
+ (( T
a
- 77 ) x
no cell
x
(-0.00215))
Max. no. of modules
Summary of Contents for Atakama ATK-P60
Page 1: ...use...
Page 3: ...3 4 6 8 10 13 14 16 20 22 33 35 41...
Page 10: ...9 on Operation with the cell in the shade...
Page 22: ...ofthemodules 21 cable glands...
Page 33: ......
Page 34: ......