Response Codes
000:XXXX
Sensor Chip ID. This is sent at boot time, and also when the status
command is issued.
0XX:XXXXXX...
Sensor registers. This message gives the address and contents of a chip
register. 16 bytes of register data will be sent on each line.
100: Booted
This is the first string sent when the Camera boots. It will later be
augmented with a firmware version number.
102: Default loaded
A message sent a boot time after the sensor and clock have been
programmed.
104: Sensor updated
A response that follows the "ly..." command.
106: Preset updated
A response that follows the "le..." command.
108: CameraLink SI-3300
2.12.30
Output by the ‘s’ status command.
Identifies the camera model, interface and firmware version
110: XXXXXX Clock
Output by the ‘s’ status command. It gives the current clock setting.
114: Clock updated
A response that follows the "lc..." command.
120: XXXX Sensor Tag
Output by the ‘s’ status command. It provides the factory serial number.
152: serial to 57.6kbaud
Response to an ‘h’ command
159: serial rate fault
A serial framing error occurred in high-speed serial mode. Camera will
return to default 9600 baud.
190: XXXX Configuration
Code
Output by the ‘s’ status command. It gives the current configuration.
501: Unrecognized
Command
The first character of the command line input is unrecognized.
503: Invalid Input
There are multiple forms of the 503 message code. They represent invalid
input other then the command specifier, such as "ly..." commands which
include to many characters of input, or not enough to fill the specified data
byte count.
505: busy
Further input was given while the camera was still processing the previous
input
601: Loaded preset #1
A response to “1” command. Preset #1 was loaded.