Frame Timing Registers
Register
Name
Default
Description
0x03
Height
0x05FF
(1535)
Number of rows – 1. Min = 0x0001. (Bits 10~0)
Note: Register value must be an odd number.
0x04
Width
0x07FF
(2047)
Number of columns – 1. Min = 0x0001. (Bits 10~0)
Note: Register value must be an odd number.
0x05
Horizontal Blanking
0x008E
(142)
Number of extra blanking clocks in row. Min = x0015(21). (Bits 10~0)
Horizontal Blanking = 390 (Regx05 - 21)
0x06
Vertical Blanking
0x0019
(25)
Number of rows + 1 in vertical blanking. Min = x0003 (3). (Bits 10~0)
Typically used to slow down frame rate and allow time for register
updates between images.
Frame Timing
Note: Typically, the value of
Expsoure
(Reg0x09) is limited to the number of rows per frame (which includes vertical
blanking rows) such that the frame rate is not affected by the integration time. If Reg0x09 is increased beyond the
total number of rows per frame, the camera will automatically increase vertical blanking (Reg05) as needed, and
thereby reduce the effective frame rates.