![Silicon Graphics Altix XE320 User Manual Download Page 145](http://html.mh-extra.com/html/silicon-graphics/altix-xe320/altix-xe320_user-manual_1271640145.webp)
Advanced Setup
007-5466-001
117
Advanced Processor Options
CPU Speed
This is a display that indicates the speed of the installed processor.
Frequency Ratio
This feature enables you to set the internal frequency multiplier for the CPU. The options are:
Default, x12, x13, x14, x15, x16, x17 and x18.
Core-Multi-Processing
Set to Enabled to use a processor's second core and beyond. (Please refer to Intel's web site for
more information.) The options are Disabled and Enabled.
Machine Checking
Set to Enabled to activate the function of Machine Checking and allow the CPU to detect and
report hardware (machine) errors via a set of model-specific registers (MSRs). The options are
Disabled and Enabled.
Thermal Management 2
Set to Enabled to use Thermal Management 2 (TM2), which will lower CPU voltage and
frequency when the CPU temperature reaches a predefined overheat threshold. Set to Disabled to
use Thermal Manager 1 (TM1), allowing CPU clocking to be regulated via CPU Internal Clock
modulation when the CPU temperature reaches the overheat threshold.
C1 Enhanced Mode
Select Disable to disable the Standard C1 Halt State, which will partially turns off the CPU
internal clocks to conserve energy and prevent system overheating when the OS is idle. Select
Enable to use the Enhanced C1 Halt State to lower the CPU clock frequency and the supply
voltage before turning off the clocks.
Summary of Contents for Altix XE320
Page 1: ...SGI Altix XE320 System User s Guide 007 5466 001 ...
Page 3: ...007 5466 001 iii Record of Revision Version Description 001 February 2008 Initial publication ...
Page 4: ......
Page 16: ......
Page 20: ......
Page 28: ......
Page 45: ...Install the System into a Rack 007 5466 001 17 Figure 2 6 Install the Server in a Rack ...
Page 52: ......
Page 56: ......
Page 84: ...56 007 5466 001 4 Advanced Node Board Setup Figure 4 9 Replace DIMMs ...
Page 110: ......
Page 119: ...Power Supply 007 5466 001 91 Figure 5 6 Power Supply Replacement Power supply Lever 2 1 2 1 ...
Page 120: ......
Page 160: ......
Page 182: ...154 007 5466 001 B IPMI 2 0 Management Utility CD ROM Image Figure B 3 CD ROM Image ...
Page 184: ...156 007 5466 001 B IPMI 2 0 Management Utility Drive Redirection Figure B 4 Drive Redirection ...
Page 198: ...170 007 5466 001 B IPMI 2 0 Management Utility Figure B 10 User Console Settings ...
Page 216: ...188 007 5466 001 B IPMI 2 0 Management Utility Figure B 19 Device Information ...
Page 230: ......
Page 238: ......
Page 242: ......
Page 248: ......