7.11
Sostituzione e/o tensionamento della cinghia
Worn or loose belts (T) must be replaced or adjusted so as to ensure safe and proper operation of the cutting tool/
brush.
• Tension:
ATTENTION: remove the mains plug.
1)
Remove the two pads
(Fig. 51)
.
2) Loosen the 3 screws (M1) and remove the top cover (M) (Fig. 52).
3) Push the belt tightener (P1) downwards to tighten the belt.
4) Secure the belt tightener with the screw (P2).
• Replacement:
ATTENTION: remove the mains plug.
1)
Remove the two pads
(Fig. 51)
.
2) Loosen the 3 screws (M1) and remove the top cover (M) (Fig. 52).
3) Remove the brush (chap.7.1).
4) Remove the 3 screw (M2) to remove the protective cover (Fig. 53).
5) Loosen the screw (P2) and remove the belt tightener (P1) (Fig. 54).
6) Loosen the 4 screws (S1) of the plate motor (Fig. 55).
7) Raise the motor and remove the worn belt (Fig. 56).
8)
Fit the new belt.
9) Tighten the 4 screws (S1).
10) Fit the belt tightener (P1) and push it downwards to tighten the belt.
11) Secure the belt tightener with the screw (P2).
12) Replace the protective cover and secure it with the 3 screws (M2).
13)
Replace the brush.
14) Replace the top cover and secure with the 3 screws (M1).
M1
M
Fig. 51
Fig. 52
Operating manual
REKORD PRO d-12
Copyright Silca S.p.A 2022
29