6
REGULATION AND USE OF THE MACHINE
6.1
Checking and setting
The cutting tool on the SMARTY 2000 is the part used to cut the key blanks and should be periodically
checked and replaced, if necessary.
Every time the cutting tool is changed, and during periodical operational tests, check calibration.
6.2
Calibration
The SMARTY 2000 key-cutting machine requires two types of calibration: axis and depth.
Axis calibration:
Axis calibration is regulation of the space between the stop and the cuts (fig.7). The axis setting for the
SMARTY 2000 is fixed and is established on assembly in our workshops.
Fig. 7
Depth calibration:
Depth calibration is regulation of the cutting depth (fig.8-A).
Proceed as follows:
1) ensure that the key-cutting machine is off by unplugging the power cable.
2) place the adjustment plates (provided) on the clamps (fig.8-B).
3) check that the adjustment plates adhere properly to the clamps (fig.8-B).
4) turn the calibration rod towards the operator so that the gauges (B1) come into contact with the
adjusting keys (fig.8-B).
5) raise the carriage and take up to the cutting tool (F).
6) take the keys into contact with the cutting tool and tracer point.
7) turn the cutting tool anticlockwise manually and check that it skims the adjusting keys in several
places.
8) if necessary, regulate the depth of the cut with the micrometric tracer point, as follows (fig.14, page
a) loosen the screw (C1) holding the tracer point (C) (fig.14, page 20).
b) turn the grub screw (C2) clockwise to advance the tracer point.
c) turn the grub screw (C2) anticlockwise to return.
9) repeat these operations until regulation is complete, then tighten the tracer point locking grub screw
(C1).
Fig. 8