SG121
Adjustment English
SG121 · Date
28.08.2019 · Art.
No.
89730 · Mod.
status
212/19
18
4.3 Electrical installation
For details on the electrical connections please refer to the encoder docu-
mentation.
5 Adjustment
For reference point adjusting the encoder must only be rotated in counter-
clockwise direction.
1. For adjusting the reference point loosen the screws
6
)
until the encoder can be turned.
2. Rotate the encoder in arrow direction until the reference point is
reached; then re-tighten the screws.
6 Commissioning
Please ensure that the instructions given in chapter
regarding mechani-
cal and electrical connection are followed. This will ensure correct instal-
lation and the operating reliability of the device.
Before starting check again:
• correct polarity of the supply voltage.
• correct cable connection.
• correct mounting of the device.
7 Transport, Storage, Maintenance and Disposal
Transport and storage
Handle, transport and store wire-actuated encoder with care. Pay atten-
tion to the following points:
•
Transport and / or store wire-actuated encoder in the unopened origi-
nal packaging.
•
Protect wire-actuated encoder from harmful physical influences
including dust, heat and humidity.
•
Do not damage connections through mechanical or thermal impact.
•
Prior to installation inspect the wire-actuated encoder for transport
damages. Do not install damaged wire-actuated encoders.
NOTICE