MSA510/1
Technical data English
MSA510/1 · Date
04.05.2016 · Art.
No.
83520 · Mod.
status
38/16
40
Mounting (
Fig. 9
)
1. Mount seal
3
to screen ring
4
.
2. Slip parts
1
...
6
over outer cable.
3. Strip cable sheath, isolate conductor.
4. Shorten and turn down screen.
5. Clamp strands into socket
7
(follow connection diagram chapter
).
6. Mount parts
2
...
6
. Place screen around screen ring
4
.
7. Screw pressure screw
1
on coupling sleeve
5
.
Fig. 9: Straight mating connector M12
10 Technical data
Mechanical data
Additional information
Housing
aluminium
Sensor/band reading dis-
tance
0.1 ... 1 mm
Cable sheath
PVC
Electrical data
Additional information
Operating voltage
10 ... 30 V DC
reverse polarity protected on UB
Current consumption
<125 mA
Power input
<3 VA
SSI clock speed input
<500 kHz
Output circuit
SSI, RS485
Cycle time
<650 μs