![Siko MSA510/1 Installation Instructions Manual Download Page 34](http://html1.mh-extra.com/html/siko/msa510-1/msa510-1_installation-instructions-manual_1270546034.webp)
MSA510/1
Commissioning English
MSA510/1 · Date
04.05.2016 · Art.
No.
83520 · Mod.
status
38/16
34
Hex
TX RX S P R Function
16 Hex 3
6
-
-
-
read out position value
18 Hex 3
6
-
-
-
read out calibration value
1b Hex 3
6
-
-
-
read out device's characteristics
D-Byte 1: identifier = 23
D-byte 2: software version
D-byte 3: hardware version
1d Hex 3
6
-
-
-
read out counting direction
value = 0: "up" (+)
value = 1: "down" (-)
1e Hex 2
3
-
-
-
read out resolution
0= 10 mm; 1= 1 mm; 2= 0.1 mm; 3= 0.01 mm;
4= 1 inch; 5=0.1 inch; 6 = 0.01 inch; 7 = 0.001 inch
28 Hex 6
6
S P -
program calibration value
Value to which the position value is set when the
sensor is zeroed (command 0x48).
2d Hex 6
6
S P -
program counting direction
value = 0: "up" (+)
value = 1: "down" (-)
2e Hex 6
6
S P -
program resolution
value range see command "1e Hex"
32 Hex 3
3
-
-
-
programming mode ON
for parameter programming (0x28 and 0x2d), pro-
gramming mode must be "ON"
33 Hex 3
3
-
-
-
programming mode OFF
default
3a Hex 3
6
-
-
-
send system status
3b Hex 3
3
-
-
-
delete system status
System status bytes 2 and 3 are deleted.
48 Hex 3
3
S P -
Sensor zeroing
Position value is set to calibration value.
4f Hex 3
3
-
-
R freeze position value
Position value is freezed; the status is reset by
reading out the position value. Used for synchro-
nized readout of multiple sensors.
Error messages
The slave (sensor) recognizes transmission or input errors and then issues
the following error messages:
Hex
TX RX S P R Function
82 Hex
-
3
-
-
-
check sum data transmission error
83 Hex
-
3
-
-
-
illegal or unknown command
85 Hex
-
3
-
-
-
illegal value (parameter programming)
Summary of Contents for MSA510/1
Page 42: ...MSA510 1 42 ...