Functional Description
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 20 of 44
Description
Display
Chapter
Firmware Revision
VERSoN
Table 13: "Device data" menu
3.7.2
Restore factory settings
There are various options for restoring the factory settings of the device:
Access
Coding
Factory settings are restored
Manual
011100
all parameters
ALL
all parameters
Interface
130 (82h) all parameters
Table 14: Access to factory settings
3.8
Warnings / Errors
3.8.1
Warnings
Warnings have no influence on the recording of the actual value.
Warnings are deleted after removing the cause.
Possible warnings:
Battery voltage for absolute position detection is below limit
immediately exchange
battery!
This warning is displayed with a blinking battery symbol. Warning messages are output via
the interface via the StatusWord (see chapter
Display
Bit assignment in the StatusWord Error
flashing bs11_BatteryState
Low battery voltage (critical)
PositionValue is still valid!
Table 15: Warnings
3.8.2
Errors
Calibration may also be required Depending on the error type.
Error states are signaled via display (written in red or battery symbol) and interface. The
cause of the fault can be determined using the event or error code (see chapter
and
To return to normal operation, the cause must be removed (see
). Error signaling can
then be acknowledged or deleted with the key (see chapter
).
If calibration is required, this is indicated in the display as "
CALIB
". Independent of
acknowledgment of the error status.