Parameter
AP10S
Date: 12.05.2020
Art. No. 90304
Mod. status 110/20
Page 27 of 44
4.2.6
TargetWindow
General characteristics
EEPROM
yes
Unit
User units
Value range
0 ... 1000
Default
5
IO-Link
Data type
UnsignedInteger16
Access
rw
Index
78
Sub-index
0
Datastorage
yes
Display
Menu
chPARAM
\
POSI
\
TW
4.2.7
LoopType
General characteristics
EEPROM
yes
Class
S
Unit
-
Value range
0 ... 2
Default
0
IO-Link
Data type
UnsignedInteger8
Access
rw
Index
79
Sub-index
0
Datastorage
yes
Display
Menu
chPARAM
\
POSI
\
LOOP
Parameter selection
Value
Display
Description
0
DIRECT
The target value is approached directly from
the current position.
1
POS
To compensate for the spindle play, the
target value is always approached in the
positive direction.
2
NEG
To compensate for the spindle play, the
target value is always approached in the
negative direction.