Inrush current, destruction of contacts
The contacts of operational voltage on the actuator have no starting cur-
rent limitation. Owing to internal capacitances, the starting current can
be a multiple of nominal current. If operational voltage is switched on vai
switching of contacts, the contacts can be destroyed or welded together.
`
Use a power pack which limits the peak value of output current to a
value admissible for the contact.
`
Switch power input of the power pack rather than output voltage.
Electromagnetic compatibility (EMC)
The following measures are required in order to ensure the actuator's elec-
tromagnetic compatibility:
`
Provide a separate power adapter for the supply of one or multiple
SIKO actuators.
`
All lines for connecting the actuator must be shielded.
`
The cable shield must be applied to both sides.
`
The drive is to earthed via the flat connection with a strand section of
at least 2.5 ... 4 mm².
Basically, all connections are protected against external interference.
Choose a place of operation that excludes inductive or capacitive interfer-
ence influences on the actuator. When mounting the system keep a maxi-
mum possible distance from lines loaded with interference. If necessary,
provide additional installations including screening shields or metallized
housings.
Ethernet pin configuration
•
1
Port1: socket 4-pole M12 D-coded (
).
•
2
Port2: socket 4-pole M12 D-coded (
).
For accessory mating connectors and cable extensions refer to chapter
PIN
Designation
1
Tx+
2
Rx+
3
Tx-
4
Rx-
WARNUNG
CAUTION
NOTICE
M12 D-Codiert 4-pol.
Buchse
2
3
4
1
viewing side = plug-in side
Port1 und Port2