AG02
Installation English
AG02 · Date
31.10.2012 · Art.
No.
82270 · Mod.
status
354/12
46
4.4 Calibration switch connection (only ABM)
The calibration switch is connected via the 12-pin connector
6
(
The input operates high-active, which means that calibration of the actua-
tor is performed upon applying of 24 VDC to the device's + input.
The input of the calibration switch is optodecoupled.
4.5 Limit switch/enable connection (only ABM)
Case 1: with limit switch and enable
The two limit switches and the enable are connected via the 12-pin con-
nector
6
(
). With the limit switch deactivated, a 24 VDC voltage
must be applied on the +input. For the drive to be moved, a 24 VDC vol-
tage must be applied on the Enable input as well.
These 24 VDC can on demand be drawn from the clips Pin "E" and "M".
This allows an economic wiring.
Please note that the galvanic separation between the unit supply and the
control input is in this case nonexistent.
The inputs of the limit switches or enable, resp., are opto-decoupled.
Case 2: without limit switch and enable
If no limit switches or enable are required, 24 VDC must be applied perma-
nently to the inputs of the limit switches or enable!
Suggestion to PIN-bridging:
24 V output
Limit switch 1 ES1 (24 V)
Limit switch 2 ES2 (24 V)
Enable (24 V)
GND ES
GND
If limit switch 1 or limit switch 2 is inactive, this is signalled by a green LED
). If enable inactive, this is signalled by a red LED (see
NOTICE
NOTICE