![Siko 6007422 Translation Of The Original Installation Instructions Download Page 45](http://html1.mh-extra.com/html/siko/6007422/6007422_translation-of-the-original-installation-instructions_1270580045.webp)
AG02
Installation English
AG02 · Date
31.10.2012 · Art.
No.
82270 · Mod.
status
354/12
45
4.3 Interface connection (RS232/RS485/only ABM)
The serial RS232 or RS485 interface is connected via 12-pin connector
6
).
Fig. 7: Connections AG02
1
PE (3x 6,3)
2
Network
3
red: fault or enable inactive
4
yellow: profibus (optional)
5
Bus Out
6
limit switch, interface, calib-
ration switch, enable
7
green: limit switch 1
8
green: limit switch 2
9
Bus In
Fig. 8: Pinout schema RS232 interface
Interface
RS232
Interface
RS232
AG02
PC
Apply screen to PE
Fig. 9: Pinout schema RS485 interface
Interface
RS485
Interface
RS485
AG02
PC
Apply screen to PE