AG03/1
Technical data English
AG03/1 · Date
30.05.2022 · Art.
No.
86426 · Mod.
status
116/22
57
Electrical data
Additional information
Parameter memory
10
5
cycles
also applies to calibration pro-
cedures
Rated current
2.4 A ±10 %
at max. admissable torque (out-
put stage)
<100 mA
at 24 V DC (control), only CAN,
PB, S3/09, IOL, IOL2
Digital inputs
17 … 30 V DC, typically 10 mA
fieldbus CAN/F + PB/F
Status display
two LEDs
Keys
inching operation
in the setup mode
Bus connection
CANopen
galvanic isolation
Profibus-DP
galvanic isolation
SIKONETZ5
galvanic isolation
IO-Link, IOL
galvanic isolation between oper-
ating voltage, output stage and
control
IO-Link, IOL2
galvanic isolation between oper-
ating voltage, output stage and
control
Type of connection
2x M12 connector (A coded)
5 poles, 1x socket, 1x pin (CAN)
2x M12 connector (B coded)
5 poles, 1x socket, 1x pin (PB)
2x M8 connector
4 poles, 1x socket, 1x pin
(S3/09)
1x M12 connector (A coded)
4 poles, 1x pin (CAN + PB +
S3/09)
earthing by contact pin 6.3 mm
System data
Additional information
Resolution
1600 increments/revolution
System accuracy
±0.8°
unidirectional
Repeat accuracy
±1 increments
unidirectional / bidirectional
Measruing range
±8182 turns
Failure rate
21.4 Year(s)
CAN, at 60 °C (MTBF) according
to SN29500
21.2 Year(s)
PB, at 60 °C (MTBF) according to
SN29500
21.9 Year(s)
S3/09, at 60 °C (MTBF) according
to SN29500
26.8 Year(s)
IOL, at 60 °C (MTBF) according to
SN29500
26.9 Year(s)
IOL2, at 60 °C (MTBF) according
to SN29500