Permitted power input
Torque overload
The actuator can be irreversibly damaged mechanically in case of abrupt
severe overload (e.g., block travel). Permanent overload causes the actu-
ator to be switched off (e.g., contouring error).
`
Adhere to permitted max. power data as per chapter
.
`
Avoid block travel.
`
Check drive transmission.
`
Check existing torque (adjust acceleration/speed profile, see User
manual).
Sufficiently dimension supply for the actuator. During acceleration, cur-
rent uptake can be temporarily higher than nominal current. The voltage
values depend on the device design. Refer to the technical data in chap-
ter
Operating voltage
•
Recommendation: Wire cross section min. 0,5 mm
2
•
Motor control and output stage are both supplied via the operating
voltage connection.
4.4 Connection, operating, and status elements
1
Right motion key
2
Left motion key
3
LED status
4
LED Bus
5
DIP switch
6
Operating voltage
7
Earthing
8
Profibus IN
9
Profibus OUT
2
1
3
4
5
Fig. 6: Operating and status elements
10
CANopen IN
11
CANopen OUT
12
SIKONETZ5 IN
13
SIKONETZ5 OUT
14
IOL: IOL IN, Power
15
IOL2: IOL In
16
IOL2: Power