4 Installation
Loss of type of connection/shielding
If the torque of the mating connector is too low this will result in loss of
type of protection and/or shielding.
`
Tighten the mating connector using the torque-limiting wrench of
the relevant connector vendor. Pay attention to the tightening torque
specified by the manufacturer.
`
Using a torque wrench tighten the mating connector (see chapter
,
). Manufacturer's recommendation of a suitable
torque can be obtained on request.
Tightening torque: 0.4 Nm (M8), 0.6 Nm (M12)
If the use of the torque-limiting wrench is not possible due to the mount-
ing situation, execute electrical installation before mechanical installa-
tion.
4.1 Mechanical mounting
Loss of type of protection
Actuator failure caused by worn sealing rings in the ball bearing and
radial shaft seals.
`
Operate the actuator within the admissible parameters
(see chapter
).
Destruction of main bearings
Improper installation (e. g. tension on the driving shaft) causes addi-
tional heat development and destruction of the actuator in the long term.
`
Ensure a low shaft and angle offset between shaft and accommodation
bore by applying appropriate manufacturing methods
+
Destruction of the main bearing / hollow shaft
Additional axial and radial loads cause destruction of the actuator.
`
Uncouple additional gears, cogged belt pulleys, etc. from actuator by
means of self-supported system construction.
CAUTION
NOTICE
WARNING
CAUTION
CAUTION