AG03/1
Installation English
AG03/1 · Date
30.05.2022 · Art.
No.
86426 · Mod.
status
116/22
37
Actuator failure
`
When mounting pay attention to the IP type of protection (see chap-
ter
).
`
Owing to the type of protection screw all mating connectors (see chap-
ter
) to the actuator by applying min. 1 Nm.
`
Do not open the actuator yourself (exception: see chapter
).
`
Avoid impact on the device.
`
Do not modify the device in any way.
Preparing mounting (
):
1. Make bore (øD1 or øD2) with distance (L1 or L2) to the driving shaft
3
.
2. Observe max. length (L3) and diameter (ød) of shaft
3
.
3. Untighten the M5 screw in the torque support
2
and M4 screw in the
clamping ring
4
respectively grub screw
5
.
Mounting (
,
):
1. Slide the actuator on the shaft
3
until the torque support has
reached the stopper (
1
or
2
).
2. Tighten the clamp ring screw
4
by applying 2,5 Nm, or grub screw
5
.
3. Tighten the screw for the torque support
2
by applying ≤2 Nm.
L
1
L
2
D1
D2
d
L3
Fig. 1: Mounting dimensions
2
1
3
dim. øD1 ø6
H9
dim. øD2 ø13 - ø14
dim. L1
30 ±0,1
dim. L2
95
dim. L3
suggestion
30 (Fitting length)
dim. ød
suggestion
ø14
f8
(clamp ring)
ø12
f8
(clamp ring)
ø10
f8
(feather key groove)
Tab. 1: Mounting dimensions
CAUTION