5-9
Section 5
T
roubleshooting
Description
: Paper runs out.
Measure
: Set new paper.
=> Section 2 Basic Operations (Paper Replacement)
Description
: Paper with an invalid size (less than 297 mm width or 64
inch width or more) is set.
Measure
: Set paper with a correct size.
=> Section 2 Basic Operations (Paper Replacement)
Description
: Paper skews.
Measure
: Set paper correctly.
Ink may be attached to the platen according to skew
conditions. Wipe off ink on the platen.
=> Section 2 Basic Operations (Paper Replacement)
Description
: The lever is in the up-position.
Measure
: Set paper according to the message.
- Error LED is blinking
Description
: Winding failed in the winder.
Measure
: Remove the paper in the vicinity of winding sensor.
Check if the paper is set correctly.
=> Section 2 Installing Paper on Winder
LIFT LEVER
CHECK PAPER
LIFT LEVER
SET PAPER
LIFT LEVER
SET PAPER
When an Error Message Appears
(Paper)
SET PAPER
PUSH DOWN LEVER
Summary of Contents for IP-6600