User Manual
2614 Texoma Drive Denison, TX 75020 • 980 Contract St. Suite 110 Lexington, KY
Phone: 903-462-7700 or toll free 800-899-5655 • Fax: 800-966-6834
29
3.4 Menu Items Cont’d
Menu or Key Function
Setting
Default
[ MISC ]
19200, e, 7, 1, p 19200pbs, 7 Bits with EVEN Parity
19200, n, 8, 1, p 19200pbs, 8 Bits with NO Parity
19200, o, 8, 1, p 19200pbs, 8 Bits with ODD Parity
19200, e, 8, 1, p 19200pbs, 8 Bits with EVEN Parity
Firmware
Version
To display the version number of Firmware and FPGA code.
Select Language
To select displayed languages on LCM panel in English, Spanish,
Italian, Deutsch, Japanese, Portuguese, Polish, Turkish or French.
English
Select Units
Provide four-unit systems for user convenience.
cm/gram; inch/oz;
cm/oz; inch/gram
Metric
Image Scale
Length
To adjust the image scale of media length and width that may be
caused by the thickness of the media.
The Numerator is the ideal length, and the Denominator is the
actual length measured from the result.
For example, cutting a line with 500.0 mm length. The procedure as
follows:
1. Press the [LEFT ARROW] to choose the Numerator and
select 500.0 mm,
2. Cut the length by sending a graph file,
3. Measure the length then use the [RIGHT ARROW] key to
choose the Denominator, then
4. Press [UP ARROW /DOWN ARROW] to change the values of
the actual length.
500/500 mm
Image Scale
Width
Scale Length
Fixed scaling, for maintenance only.
Scale Width