9
Fig 9
Fig 11
Flashing green light
Continuous green light
Continuous red light
This tool is provided with a safety
logic device to prevent accidental
starting of the welding process
(e. g. when carrying the tool with the sealing
lever). For this reason the strap must first be
tensioned to a minimum tension to start the
welding process (press yellow button).
Push lever to stop (sealing position). The left
hand remains on the handle of the tool to bear
the counterforce.
The straps are welded together and
the upper strap is cut off. The
signal lamp (10/1) indicates the
following functions
After finishing the
friction welding, the
green light flashes for
approx. 2 sec. The
sealing lever must stay
in the sealing position,
during this time.
When the green light is
on continuously, the
sealing cycle is finished.
When the red light is on
continuously, the battery
must be charged (see
chapter 5.2).
When the red signal lamp lights up,
the unit is blocked, since the
remaining charge in the battery is
insufficient to ensure proper welding of the
straps.
Press lever against the handle. Then swing the
tool away from the strapping to the right at the
rear.
If the straps are poorly welded,
check the setting of the welding
time (see chapter 7.2).