SR 012
S-DIAS DC MOTOR OUTPUT STAGE
Page 32
04.11.2020
8.2
Performance Level e, Category 3 or SIL 3
– Safety-SPS
To meet the requirements of safety category 3, performance level "e" for EN ISO 13849-1
and SIL 3 according to EN 62061, an error-proof output of a safety PLC must be used. The
reason of category 3 here, is that cross-circuit detection between the two lines is not possible.