S-DIAS Safety Digital Mixed Module
SDM 081
The S-DIAS Safety SDM 081 digital mixed module has the safety integrity level
SIL3
in accordance with EN / IEC 62061 or
Performancelevel e
(PL e) in
accordance with EN ISO 13849-1/-2.
The SDM 081 has:
•
2 Safe +24 V outputs with a maximum of 2 A per output
(EN 61131-2; EN / IEC 62061 und EN ISO 13849-1/-2)
•
6 Safe +24 V DC/0.5 ms inputs (EN 61131-2; EN / IEC 62061 und
EN ISO 13849-1/-2)
•
Redundant output signal (short-circuit proof)
The safe outputs are used for the safety-oriented output of two actuator
signals to, for example, control relays, valves, etc.
The safety inputs are used for reading six actuator signals (Emergency Stop,
confirmation button etc.). To test inputs and detect cross circuits (e.g.
Emergency Stop), the SDM 081 has two non-safe signal outputs, A and B.
The safety-related SDM 081 is ideal for use in systems with optional modules
and interface variables according to Safety System Handbook, see
homepage
1
.
To use the Safety digital input module in an application, the SDM 081 also
requires a Safety CPU module that regulates the synchronized communication with the safety
modules using safe bus telegrams. This also includes
•
processing the safe application and
•
the distribution of configuration data to remote safety modules.
1
Using the search function with the keyword “Safety System Handbook”
Summary of Contents for SDM 081
Page 21: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 19...
Page 23: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 21 4 Mechanical Dimensions...
Page 27: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 25 6 Wiring 6 1 Wiring Example...
Page 35: ...S DIAS SAFETY DIGITAL MIXED MODULE SDM 081 07 02 2022 Page 33 9 3 Example...