background image

 

Page 2 of 7    SLX Series 

 

CONNECTIONS: 

VIDEO 

(CONT.) 

 
16x2 CONFIGURATIONS: 
 

The 16x2 systems also offer dual outputs.  Outputs “AUX” and “OUT 1” located in the center of the input BNCs 

provides video for channel 1.  The two BNCs located on the panel without input BNCs provide channel 2 video outputs. 

 

32x1 CONFIGURATIONS: 
 

On a 32x1 configuration the following video connections are required.  On the secondary video switch module (17-

32) connect Output “B” to the primary video switch module (1-16) “AUX”.   This provides the path for inputs 17 to 32 to 
the secondary switch circuitry of the primary switch module.  Use “OUT” of the primary video switch module for video 
output to the destination equipment.  Output “A” of the secondary switch module is not used. 
 
32x2 CONFIGURATIONS: 
 

A 32x2 system has two sets of boards configured similar to the 32x1 system.  The secondary switch connections 

are made by looping the “B” outputs of the secondary switch module (17-32) to the “AUX” connector of the primary 
switch module (1-16).  The “OUT” connectors of the primary switch modules are used to switch video to the destination 
equipment. 
 
LOOPING CONFIGURATIONS: 
 

The “looping” modules have slightly different markings to designate the outputs and secondary switch 

interconnection BNCs.  In a 16x1 or 16x2 looping video configuration the BNC labeled “Output” is connected to the 
destination equipment.  The BNC connector labeled “AUX” provides a bridged output in these systems. 
 

Video signal interconnections for the looping 32 input configurations are made in the following manner.  The 

secondary video switch module (17-32) has two BNC output connectors.  Connect the BNC labeled “Output” on the 
secondary video switch module (17-32) to the BNC labeled “AUX” on the primary video switch module (1-16).  The 
BNC labeled “Output” on the primary video switch module is the output to the destination equipment. 
 
 

Typically the video inputs are Sync Tip Clamped (STC) on composite video systems.  Jumper W2 provides this.  To 

AC couple the inputs, move the jumper from W2 to W3 (Multi-Channel Systems). 

AUDIO: 

 

Audio signal connections are made via the detachable three position screw terminals.  Each of the inputs and 

output(s) has their own detachable connector.  This provides a convenient means of wiring a given input or output 
without disturbing the other audio interfaces.  Each of the balanced audio connections; (+), (C) and (-); are marked on 
the detachable connectors.  
 

The primary audio switch module used for inputs 1-16 has a single input connector labeled “Inputs 17-32.”  This 

input comes from the output of the secondary audio switch module for inputs 17-32, if present.  The system output 
connector will always be on the primary audio switch module. 
 

The Analog audio connections are a high impedance bridging input.  This allows the inputs to be bridged from one 

switch module to the input of a second switch module in a two (2) output system, i.e. SLX-162 and SLX-322 systems. If 
it is desired to have the incoming signal terminated into a 600

 load, it is necessary to add a 600

, 1/2 Watt resistor 

across the (+), (-) terminals of the input connector.  When bridging the inputs, the 600

 load should only be attached to 

the last connector in any given audio bridge. 
 

The Digital audio connections are transformer coupled 110

 impedance in and out per AES-3 1992 standard. 

 

Summary of Contents for SLX series

Page 1: ...SLX SERIES ANALOG and DIGITAL SOURCE SELECT SWITCHERS OPERATORS MANUAL SCI PROTOCOL APPENDIX SIGMA ELECTRONICS INC P O BOX 448 1027 COMMERCIAL AVENUE EAST PETERSBURG PA 17520 717 569 2681...

Page 2: ...nnels The line cord is configured for the line voltage requirement of the frame either 115 VAC or 230 VAC The same power supply is used in both 1RU and 2RU frames The only difference in the two config...

Page 3: ...secondary video switch module 17 32 has two BNC output connectors Connect the BNC labeled Output on the secondary video switch module 17 32 to the BNC labeled AUX on the primary video switch module 1...

Page 4: ...the 9 Pin D connector on the rear of the SCI 161 module located in the left rear position of the master frame The SCI accepts either RS 232 or RS 422 format control signals from external devices Detai...

Page 5: ...to the output Note that the previously selected video signal will remain connected to the output throughout this process A split switch of the video and audio signals can be performed as follows Firs...

Page 6: ...s video amplitude to 1 Vp p C6 Frequency Response adjusts for maximum bandwidth optimized flat response C3 Frequency Response adjusts for secondary feed through of input signals 17 to 32 DIGITAL VIDEO...

Page 7: ...RS BNC DIGITAL VIDEO INPUT SMPTE 259M A B C D 800mV p p maximum 75 terminated DATA RATE 143 177 270 360 Mbps OUTPUT SIGNAL 800 mV p p maximum 10 OUTPUT to OUTPUT ISOLATION 20 dB minimum 5 MHz to 270 M...

Page 8: ...483 x 44 X 210 mm 2 RU FRAME 19 W x 3 5 H x 8 3 D 483 x 87 X 210 mm WEIGHT 1 RU FRAME 10 lb 4 5 kg Typical Configuration Dependent 2 RU FRAME 14 lb 6 4 kg Typical Configuration Dependent TECHNICAL MAN...

Page 9: ...e request and executes the change it will respond with an ASCII message OK unless disabled see N Y command explanation The ASCII protocol for making a BREAKAWAY is AxxOxx RETURN ENTER The A could actu...

Page 10: ...on X XX Month Day Year RS422 CONTROL Unlike RS232 RS422 allows for multiple devices to be connected to a computer terminal at the same time In order for the computer terminal to communicate with a dev...

Page 11: ...internal Switch settings shown provide 16x1 configuration for 3200 protocol MATRIX SIZE SELECTION S2 1 S2 3 PROTOCOL SELECT S2 1 S2 2 S2 3 Matrix Size Control Configuration S2 4 Protocol ON ON ON 32...

Page 12: ...Ground Same as standard ANSI SMPTE 207M 1984 SCI SLX 9 PIN D RS 232 PIN ASSIGNMENT PIN FUNCTION DIRECTION 1 N C 2 RECEIVE DATA INPUT 3 TRANSMIT DATA OUTPUT 4 DATA TERMINAL READY OUTPUT 5 SIGNAL GROUN...

Page 13: ...ons with the SCI SLX The above wiring chart is typical for most IBM and compatible type PC s However it is always best to check with the manufacturer s wiring specifications to determine exact pin ass...