Page 1 of 7    SLX Series 

 

SLX SERIES 

 

RECEIVING: 

 

It is recommended that the SLX Series switcher be inspected upon receipt.  Report any damage to the shipping 

company and to SIGMA ELECTRONICS, INC.  Shipping cartons should be saved for use in the unlikely event that a 
return shipment is necessary. 
 

 
GENERAL: 
 

The Source Select Switchers are ideal for applications utilizing standard bandwidth to high-resolution analog video 

signals, mono or stereo analog audio, digital audio and serial digital video.  The available configurations of the SLX 
Series include 16 or 32 inputs by 1 or 2 outputs.  Selection of input-to-output switching is achieved via the integral front 
control panel. This control panel allows audio-follow-video, split, or breakaway modes.  An additional control panel can 
be remotely located if an optional Remote Control Panel has been purchased. 
 

The SLX Series master frame provides a serial port, which will accept RS-232 or RS-422 control data.  The SLX 

Series Control Protocol section of this manual provides information on the serial port. 
 

The SLX Series switchers are flexible in configurations of video and audio channels.  They can be simply a single 

video channel, or audio only.  Video can be combined with audio in either Mono or Stereo configurations.  The system 
may be configured for multiple channels of video for YC or RGB applications.  Sync pulse signals of -4 Vp-p can also 
be switched via specially modified video boards.  Many system configurations are provided by Sigma sales literature 
but the SLX Series is not limited to those common configurations. 
 

 
POWER:

 

 

Each frame of an SLX Series system contains a power supply to support the modules within that frame.  The 

number of frames required to build a system will depend upon the number of video and audio channels.  The line cord 
is configured for the line voltage requirement of the frame, either 115 VAC or 230 VAC. 
 

The same power supply is used in both 1RU and 2RU frames.  The only difference in the two configurations is the 

metal back panel to accommodate the frame size.  The power supply contains a step-down transformer and rectifiers, 
which produce three unregulated voltages; +9VDC, +17 VDC, and -17 VDC. Each module within the frame has 
regulators, which produce the regulated DC bus voltages for the required circuitry.  The module may contain regulators 
for +5 VDC, -5 VDC, +12 VDC, and -12 VDC. 
 

 
FRAMES: 

 

Frames are provided in a 1RU or 2RU size dependent upon the number of modules required to configure the 

system.  The local control panel is attached to the front of the frame.  Each frame within a system contains a power 
supply, video modules, and/or audio modules.  Only the master frame contains an SCI (system control interface) 
module.  Control data is looped from the master frame to each of the other slave frames via an external cable that is 
supplied with the SLX switcher. 
 

 
CONNECTIONS: 

VIDEO: 

 

Digital and analog video signals connect to the SLX Series by a common method.  BNC style connectors are used 

for video inputs as labeled on the rear of the unit.  Inputs are labeled 1-16 or 1-32 based on the system configuration.  
The system, as configured at the factory, provides inputs terminated into a 75

 load or looping.  The looping systems 

are indicated by the addition of an (L) suffix, i.e. SLX-161 VO(L) supplies 16 inputs with non-terminated BNC loop 
through. 
 

The output connectors are located in the center of the video switch module.  The output BNC connectors are 

marked on the printed circuit board.  Depending upon the function of the module, the video BNCs will be marked as 
described below. 
 
16x1 CONFIGURATIONS: 
 

The outputs are provided by the “AUX” and “OUT” BNCs.  This dual output provides the same video signal on both 

BNCs.  When a video switch is performed both outputs switch simultaneously. 

Summary of Contents for SLX series

Page 1: ...SLX SERIES ANALOG and DIGITAL SOURCE SELECT SWITCHERS OPERATORS MANUAL SCI PROTOCOL APPENDIX SIGMA ELECTRONICS INC P O BOX 448 1027 COMMERCIAL AVENUE EAST PETERSBURG PA 17520 717 569 2681...

Page 2: ...nnels The line cord is configured for the line voltage requirement of the frame either 115 VAC or 230 VAC The same power supply is used in both 1RU and 2RU frames The only difference in the two config...

Page 3: ...secondary video switch module 17 32 has two BNC output connectors Connect the BNC labeled Output on the secondary video switch module 17 32 to the BNC labeled AUX on the primary video switch module 1...

Page 4: ...the 9 Pin D connector on the rear of the SCI 161 module located in the left rear position of the master frame The SCI accepts either RS 232 or RS 422 format control signals from external devices Detai...

Page 5: ...to the output Note that the previously selected video signal will remain connected to the output throughout this process A split switch of the video and audio signals can be performed as follows Firs...

Page 6: ...s video amplitude to 1 Vp p C6 Frequency Response adjusts for maximum bandwidth optimized flat response C3 Frequency Response adjusts for secondary feed through of input signals 17 to 32 DIGITAL VIDEO...

Page 7: ...RS BNC DIGITAL VIDEO INPUT SMPTE 259M A B C D 800mV p p maximum 75 terminated DATA RATE 143 177 270 360 Mbps OUTPUT SIGNAL 800 mV p p maximum 10 OUTPUT to OUTPUT ISOLATION 20 dB minimum 5 MHz to 270 M...

Page 8: ...483 x 44 X 210 mm 2 RU FRAME 19 W x 3 5 H x 8 3 D 483 x 87 X 210 mm WEIGHT 1 RU FRAME 10 lb 4 5 kg Typical Configuration Dependent 2 RU FRAME 14 lb 6 4 kg Typical Configuration Dependent TECHNICAL MAN...

Page 9: ...e request and executes the change it will respond with an ASCII message OK unless disabled see N Y command explanation The ASCII protocol for making a BREAKAWAY is AxxOxx RETURN ENTER The A could actu...

Page 10: ...on X XX Month Day Year RS422 CONTROL Unlike RS232 RS422 allows for multiple devices to be connected to a computer terminal at the same time In order for the computer terminal to communicate with a dev...

Page 11: ...internal Switch settings shown provide 16x1 configuration for 3200 protocol MATRIX SIZE SELECTION S2 1 S2 3 PROTOCOL SELECT S2 1 S2 2 S2 3 Matrix Size Control Configuration S2 4 Protocol ON ON ON 32...

Page 12: ...Ground Same as standard ANSI SMPTE 207M 1984 SCI SLX 9 PIN D RS 232 PIN ASSIGNMENT PIN FUNCTION DIRECTION 1 N C 2 RECEIVE DATA INPUT 3 TRANSMIT DATA OUTPUT 4 DATA TERMINAL READY OUTPUT 5 SIGNAL GROUN...

Page 13: ...ons with the SCI SLX The above wiring chart is typical for most IBM and compatible type PC s However it is always best to check with the manufacturer s wiring specifications to determine exact pin ass...

Reviews: