background image

 

Page 3 of 7    SLX Series 

 

ANALOG AUDIO CONFIGURATIONS

 

The source and destination audio devices must be evaluated to determine if they utilize balanced or unbalanced 

outputs and inputs.  After determination is made, refer to the drawings provided to select the proper audio wiring.  All 
inputs should be the same configuration.  If both balanced and unbalanced inputs are used, gain variations will occur 
as noted below.  In those applications, the audio signal levels should be adjusted before connection to the switcher. 
 
 
 
 
 
 
 
 
 

Balanced In to Balanced Out 

Balanced In to Unbalanced Out 

 

V out = V in 

V out = 0.5 V in 

 
 
 
 
 
 
 
 

Unbalanced In to Balanced Out 

Unbalanced In to Unbalanced Out 

 

(-) Input Grounded; V out = V in 

V out = 0.5 V in 

 

(-) Input Floating: V out = 0.75 V in 

 

 

The input to output level comparison provided in the figures above, assumes the outputs are terminated into a 

600

 load.

 

CONTROL: 

 

External control of the SLX Series may be performed by a Remote Control Panel or another serial control system. 

This is accomplished via the 9 Pin D connector on the rear of the SCI-161 module, located in the left rear position of 
the master frame. The SCI accepts either RS-232 or RS-422 format control signals from external devices.  Details on 
the interface parameters and format selection are covered in the SLX Series Control Protocol section of this manual. 
 

Systems comprised of multiple frames require the control information to be looped from the master frame to each 

slave frame.  The 9 Pin D connector located on the power supply module is used for the purpose of looping the control 
information. 

**NOTE** 
Due to a change in system processor, the communication parameters Bits/Character, and Parity, are no longer 
available.  Default settings are now 8 Bits/Character and No Parity.  To determine whether a system has this change, 
enter the command “V”, for version, when the system is in a working communications mode.  Systems with the new 
processor will respond with “Sigma Electronics Copyright 2002, SCI-162 firmware version X.XX  {Month Day Year}”.  
Earlier systems that have the Bits/Character, and Parity parameters set by the user will respond to the “V” command 
with “?”. 

 



IN OUT 







IN 



OUT 







Open 


Gnd 

IN OUT 








Gnd 

IN OUT 







Open 

Summary of Contents for SLX series

Page 1: ...SLX SERIES ANALOG and DIGITAL SOURCE SELECT SWITCHERS OPERATORS MANUAL SCI PROTOCOL APPENDIX SIGMA ELECTRONICS INC P O BOX 448 1027 COMMERCIAL AVENUE EAST PETERSBURG PA 17520 717 569 2681...

Page 2: ...nnels The line cord is configured for the line voltage requirement of the frame either 115 VAC or 230 VAC The same power supply is used in both 1RU and 2RU frames The only difference in the two config...

Page 3: ...secondary video switch module 17 32 has two BNC output connectors Connect the BNC labeled Output on the secondary video switch module 17 32 to the BNC labeled AUX on the primary video switch module 1...

Page 4: ...the 9 Pin D connector on the rear of the SCI 161 module located in the left rear position of the master frame The SCI accepts either RS 232 or RS 422 format control signals from external devices Detai...

Page 5: ...to the output Note that the previously selected video signal will remain connected to the output throughout this process A split switch of the video and audio signals can be performed as follows Firs...

Page 6: ...s video amplitude to 1 Vp p C6 Frequency Response adjusts for maximum bandwidth optimized flat response C3 Frequency Response adjusts for secondary feed through of input signals 17 to 32 DIGITAL VIDEO...

Page 7: ...RS BNC DIGITAL VIDEO INPUT SMPTE 259M A B C D 800mV p p maximum 75 terminated DATA RATE 143 177 270 360 Mbps OUTPUT SIGNAL 800 mV p p maximum 10 OUTPUT to OUTPUT ISOLATION 20 dB minimum 5 MHz to 270 M...

Page 8: ...483 x 44 X 210 mm 2 RU FRAME 19 W x 3 5 H x 8 3 D 483 x 87 X 210 mm WEIGHT 1 RU FRAME 10 lb 4 5 kg Typical Configuration Dependent 2 RU FRAME 14 lb 6 4 kg Typical Configuration Dependent TECHNICAL MAN...

Page 9: ...e request and executes the change it will respond with an ASCII message OK unless disabled see N Y command explanation The ASCII protocol for making a BREAKAWAY is AxxOxx RETURN ENTER The A could actu...

Page 10: ...on X XX Month Day Year RS422 CONTROL Unlike RS232 RS422 allows for multiple devices to be connected to a computer terminal at the same time In order for the computer terminal to communicate with a dev...

Page 11: ...internal Switch settings shown provide 16x1 configuration for 3200 protocol MATRIX SIZE SELECTION S2 1 S2 3 PROTOCOL SELECT S2 1 S2 2 S2 3 Matrix Size Control Configuration S2 4 Protocol ON ON ON 32...

Page 12: ...Ground Same as standard ANSI SMPTE 207M 1984 SCI SLX 9 PIN D RS 232 PIN ASSIGNMENT PIN FUNCTION DIRECTION 1 N C 2 RECEIVE DATA INPUT 3 TRANSMIT DATA OUTPUT 4 DATA TERMINAL READY OUTPUT 5 SIGNAL GROUN...

Page 13: ...ons with the SCI SLX The above wiring chart is typical for most IBM and compatible type PC s However it is always best to check with the manufacturer s wiring specifications to determine exact pin ass...

Reviews: