![background image](http://html.mh-extra.com/html/sigma/chef-10/chef-10_use-and-maintenance-instruction-manual_1267775017.webp)
Instructions manual CHEF 10 VVE
17 of 19
BLOCKAGE OF MACHINERY AND NECESSARY REMEDIES
OPERATIONAL
ANOMALIES
POSSIBLE CAUSES
REPAIR
Turning the master switch into
position, the warning light does
not turn on
1) Plug not inserted correctly or wires
detached
1) Check connection
Pressing the START button, the
mixer does not start
1) The slide is not in position or the
front grid is not closed
2) Safety micro switch anomalies
1) Lift the slide and reposition it
after having closed the front
grid
2) Replace the micro switch
Intermittent noise
1) Lack of grease in transmissions
(gears)
1) Grease as shown in previous
layout (page 13)
Continuous noise
2) Check the efficiency of the
bearings
1) Replace
the