The following conditions constitute improper use of the mixer: 

 

Loading more than what is allowed or use of unsuitable ingredients. 

 

Cleaning with unsuitable tools or instruments that can scratch the bowl or damage the mixer or paint. 

 

Use of the mixer in unsuitable places. 

 
Modality for granting the warranty 
If the customer finds defects in the mixer, he must immediately inform the supplier, who will carry out a quick 
analysis of the lack of compliance and will establish the intervention mode with the customer.  
After  agreement  with  the  supplier,  the  customer must  provide  him  with  the  needed  time  and  opportunity  to 
carry  out  modifications,  improvements,  repairs  or  the  supply  of  spare  parts  which  the  supplier  deems 
reasonably necessary. If this does not occur, the supplier will not be held liable. 
 
Parts subject to wear 
 
Some components are scaled for a life duration far longer than that of normal mixer use during the time of its 
warranty.  Breakage or malfunctioning of these pieces depends on their use. They are therefore considered 
parts subject to wear and are not included in the warranty, unless they manifest evident defects in the parts 
or machinery.  
The parts subject to wear are: transmission belts, motors, bearings and bowl. 

 

 
CLEANING AND MAINTENANCE OPERATIONS. 

 
CONTROL OF INSTALLED SAFETY SYSTEMS AND ELECTRICAL SYSTEM 
The installed safety systems and the electrical system are subject to periodical checks carried out by 
a specialised electrician.  

 

Key of control intervals: 

(INTERVAL) 

Key of how to carry out the controls: 

(METHOD) 

d = daily. 
w = weekly.  
m = monthly.  
a = annually.  
 

O =  observation: requires simple eye check (i.e. alarm light) 
F  =  Function:  requires  a  physical  control  of  the  action  (i.e.  pressing  the 

emergency button the mixer must stop)  

M  =  Measurements:  requires  a  control  with  an  appropriate  instrument  (i.e. 

control of earthing values). 

 
Master switch.   
 Purpose: protection of power line.  
Function: this equipment separates the machinery from the mains, it is placed on 
the upright of the mixer, downstream the differential protection board.  
 
Stop circuit and safety micro switch of grid. 
 Purpose:  to  stop  the  mixer  immediately  and  unconditionally.  Function:    pressing 
the  STOP  button  or  lifting  the  protective  grid  cuts  the  motor  power,  stopping  the 
mixer  totally  and  not  systematically.  To  restore  functioning  of  the  machinery,  the 
operator must start the cycle once again by pressing the START button. 
 
Controls of system 
 Periodically  the  mixer's  automation  functioning  and  earthing  must  be  checked. 
The  operating  modes,  safety  functions,  terminal  board  contacts  need  to  be 
controlled  as  well  as  the  integrity  of  the  cables,  luminous  LEDs  and  earthing 
system. 

 

Control 

Interval 

Method 

Control 

Interval 

Method 

Control 

Interval 

Method 

F, M 

Summary of Contents for CHEF 10

Page 1: ...al CHEF 10 VVE 1 of 19 Via Artigianato 85 25030 Torbole Casaglia BRESCIA ITALY Tel 030 265 04 79 Fax 030 265 01 43 USE AND MAINTENANCE INSTRUCTION MANUAL CHEF 10 PLANETARY MIXER WITH ELECTRONIC SPEED VARIATION INVERTER ...

Page 2: ...where it can remain intact and where it can be consulted during the whole life of the machine INDEX SAFETY INSTRUCTIONS 3 RESIDUAL RISKS 3 RESIDUAL RISKS PROHIBITIONS OBLIGATIONS Summarised table 4 SYMBOLS USED AND QUALIFICATIONS OF THE PERSONNEL 5 USE AND DESCRIPTION OF THE MIXER 5 INSTRUCTIONS FOR USE 6 IDENTIFICATION POSITION OF THE OPERATOR AND DANGEROUS AREAS 8 TECHNICAL DATA PACKAGING DIMENS...

Page 3: ...n safe conditions and clean it with a neutral degreasing agent i e with Marseille soap Safety devices The mixer is equipped with some devices which protect its operation as well as the safety of the operator They must not be removed or modified Their functioning must be checked periodically Master switch cuts power from the mixer for maintenance in safe conditions Circuit breaker switch cuts power...

Page 4: ...ntroduce any object through the protective grid with organs in movement danger of objects being thrown Before carrying out any manoeuvre beyond the protective grid wait for the mixer to come to a complete stop Stability for machinery if there is the possibility of slipping on wet or greasy surfaces or positioning the equipment in unstable places ships planes or other use the appropriate attachment...

Page 5: ...ng courses ATTENTION This sign requests you to pay particular attention to the operations indicated Lack of compliance can cause harm to personnel or damage to the mixer USE AND DESCRIPTION OF THE MIXER BMC series planetary mixers are mixing derives which are particularly suitable for use in the hotel sector The high power motor is controlled by an electronic speed variator with a transmission rat...

Page 6: ...holes on the bowl support plates match with the centring pins Block the bowl with the handles If it was not previously done rotate the protective grid of the bowl to the open position and after having chosen the tool insert it into the tool holder shaft Once it is inserted turn the tool clockwise having the transmission pin enter the work position as indicated in the figure Lower it and insert the...

Page 7: ...xer is turned on it goes through a short two second test it verifies mains voltage grid and bowl presence alarms In the mean time full squares that pursue each other appear on the display they show the board analysis status the start and stop LED blink and then SIGMA SYSTEM appears on the screen the machine is ready for use Programming By pressing the menu button for a short a mount of time the fo...

Page 8: ...t have been inserted up until now one must press the menu key for at least two seconds and then it goes back to normal board operation OPERATION When starting up by pressing the start button the machine starts at the lowest speed the key is used to increase the selected speed until it reaches the maximum use speed that is the sixth By pressing the key instead it will decrease the speed until it re...

Page 9: ... risk of explosion An atmosphere capable to being transformed into an explosive atmosphere due to room and or operating conditions is defined a potentially explosive atmosphere The mixer was not built to work in environments with potentially explosive atmospheres IDENTIFICATION POSITION OF THE OPERATOR AND DANGEROUS AREAS There is a plate on the back of the mixer like the one shown which carries i...

Page 10: ...ructions manual CHEF 10 VVE 10 of 19 TRANSPORTATION AND HANDLING Model A mm B mm C mm Weig ht Kg Bowl litres Power Kw BMC 10 610 770 560 55 10 0 55 Packaging A mm B mm H mm Pallet cardboard box 830 570 960 ...

Page 11: ...r to protect it from humidity dust and filth If wrapped in cellophane or another type of plastic avoid airtight closing below the mixer in order to prevent corrosion linked to condensate ATTENTION The mixer must not be stored in the open INSTALLATION The mixer must stand in a vertical position on a smooth surface sufficiently sturdy for the load floor with resistance over 20 km cm 2 If in danger o...

Page 12: ...AND MAINTENANCE OPERATIONS CONTROL OF INSTALLED SAFETY SYSTEMS AND ELECTRICAL SYSTEM The installed safety systems and the electrical system are subject to periodical checks carried out by a specialised electrician Key of control intervals INTERVAL Key of how to carry out the controls METHOD d daily w weekly m monthly a annually O observation requires simple eye check i e alarm light F Function req...

Page 13: ...ANCE Should a power cable be damaged replace it with a H07RN F cable with a 3x1 5 mm2 section Cleaning the mixer is not jet proof Do not wash it with running water Clean it with a moist cloth and neutral detergents such as degreasing agents based on Castile soap A To carry out interventions not specially mentioned in the manual refer to personnel authorised by SIGMA SrL To replace the motor or the...

Page 14: ...onstruction Position description item code and desired amount of pieces requested Send the request to Sigma SrL via Artigianato 85 25030 Torbole Casaglia BS Italy MAIN COMPONENTS Raw materials used almost all of the components of the mixer are made of steel cast iron brass and plastic All of these components can be disposed of easily and do not represent a danger for environmental pollution and or...

Page 15: ...Instructions manual CHEF 10 VVE 15 of 19 SPARE PARTS LIST ...

Page 16: ...0 INTERNAL CROWN WHEEL 11 1 199023 BMC 10 CONTAINMENT BOWL 12 1 199020 BMC 10 PLANETARY 13 1 199032 BMC 10 GRID UNIT 14 1 BMC 10 BK2526 ROLLER BUSHING WITH CAP 15 1 098109 2 BMC 10 BOWL 16 1 MIM 25 47 10 17 2 BEARING 6205 2RS 25 52 15 18 1 098162 098164 098165 BMC 10 WHISK UNIT BMC 10 CAST SPIRAL BMC 10 CAST BLADE 19 2 098030 2 BOWL LIFTING GUIDE BLADES 20 1 DELTA INVERTER VFD004S1A 21 1 MV15 MICR...

Page 17: ...ached 1 Check connection Pressing the START button the mixer does not start 1 The slide is not in position or the front grid is not closed 2 Safety micro switch anomalies 1 Lift the slide and reposition it after having closed the front grid 2 Replace the micro switch Intermittent noise 1 Lack of grease in transmissions gears 1 Grease as shown in previous layout page 13 Continuous noise 2 Check the...

Page 18: ...Instructions manual CHEF 10 VVE 18 of 19 ELECTRICAL LAYOUT ...

Page 19: ...ely from other waste Differentiated waste collection of this appliance having reached the end of its life is organised and managed by the manufacturer The user who desires to dispose of the present appliance must therefore contact the manufacturer and abide by the system that has been chosen to allow separate collection of the appliance when reaching the end of its life Adequate differentiated was...

Reviews: