Programming Guide
39
< bsch >:= {CH1, CH2}
< frq_dev >:={ Default unit is
“Hz”, value range depends on the model}
< pha_dev >:={ Default unit is
“
°
”value range depends on the model }
<fcoup>,<acoup>,<pcoup>:={ON, OFF}
<frat>,<prat>,< arat >:={a ratio value. value range depends on the model }
<adev>:={ a deviation value. value range depends on the model }
QUERY SYNTAX
EXAMPLE
COUP (COUPling)?
Set SDG5000 coupling state on
COUP STATE,ON
Set SDG5000 frequency deviation value 5Hz
COUP FDEV,5
Set SDG2000x amplitude coupling ratio
COUP ARAT,2
Query SDG2000X coupling information.
COUP?
Return:
COUP\sTRACE,OFF,FCOUP,ON,PCOUP,ON,ACOUP,ON,FDEV,5HZ,
PRAT,1,ARAT,2\n
Note:
Parameter/command
SDG800
SDG1000
SDG2000X
SDG5000
SDG1000X
TRACE
no
no
yes
no
yes
STATE
yes
yes
no
yes
no
BSCH
yes
yes
no
yes
no
FCOUP
no
no
yes
no
yes
FRAT
no
no
yes
no
yes
PCOUP
no
no
yes
no
yes
PRAT
no
no
yes
no
yes
ACOUP
no
no
yes
no
yes
ARAT
no
no
yes
no
yes
ADEV
no
no
yes
no
yes
3.20 Voltage Overload Command
DESCRIPTION
Sets or gets state of over-voltage protection.
Summary of Contents for SDG5000 series
Page 38: ...SDG5000 User Manual 27 Figure 2 5 Setting the Offset ...
Page 109: ...SDG5000 User Manual 98 Figure 3 1 Sine Waveform ...
Page 111: ...SDG5000 User Manual 100 Figure 3 2 Square Waveform ...
Page 129: ...SDG5000 User Manual 118 3 12 Figure 3 12 FSK Waveform ...
Page 135: ...SDG5000 User Manual 124 Figure 3 15 DSB AM Waveform ...