Programming Guide
40
COMMAND SYNTAX
VOLTPRT<parameter>
<parameter>:= {ON, OFF}
QUERY SYNTAX
RESPONSE FORMAT
VOLTPRT<parameter>
Note:
Parameter/command
SDG800
SDG1000 SDG2000X SDG5000 SDG1000X
no
yes
yes
no
yes
3.21 Store List Command
DESCRIPTION
This command is used to read the stored wave data names if the
store unit is empty;
the command will return “EMPTY” string.
Note: M50~ M59 is user defined memory. The name will return
what you defined. if you do not define an arbitrary name, it will
return
“
EMPTY”(It is depends on the model).
QUERY SYNTAX
STL (StoreList)? BUILDIN, USER
EXAMPLE
Read all arbitrary data saved in the device.
STL?
Return:
STL M0, StairUp, M1, StairDn, M2, StairUD, M3, Trapezia, M4,
ExpFall, M5, ExpRise, M6, LogFall, M7, LogRise, M8, Sqrt, M9,
X^2, M10, Sinc, M11, Gaussian, M12, Dlorentz, M13, Haversine,
M14, Lorentz, M15, Gauspuls, M16, Gmonopuls, M17, Cardiac,
M18, Quake, M19, TwoTone, M20, SNR, M21, Hamming, M22,
Hanning, M23, Kaiser, M24, Blackman, M25, GaussiWin, M26,
Harris, M27, Bartlett, M28, Tan, M29, Cot, M30, Sec, M31, Csc,
M32, Asin, M33, Acos, M34, Atan, M35, ACot, M36, EMPTY,
M37 .
….
Read built-in wave data.
STL? BUILDIN
Return:
STL M0, Sine, M1, Noise, M10, ExpFal, M11, ExpRise, M12,
LogFall, M13, LogRise, M14, Sqrt, M15, Root3, M16, X^2,
M17, X^3, M18, Sinc, M19, Gussian, M2, StairUp, M20,
Dlorentz, M21, Haversine, M22, Lorentz, M23, Gauspuls,
Summary of Contents for SDG5000 series
Page 38: ...SDG5000 User Manual 27 Figure 2 5 Setting the Offset ...
Page 109: ...SDG5000 User Manual 98 Figure 3 1 Sine Waveform ...
Page 111: ...SDG5000 User Manual 100 Figure 3 2 Square Waveform ...
Page 129: ...SDG5000 User Manual 118 3 12 Figure 3 12 FSK Waveform ...