Specifications
Rev. 2 January 2021
39
41112510
Host Interfaces
IEC 60068-2-32
Free Fall Test
1 m drop height
6 drops onto concrete, 2 per axis: X, Y, Z
Operating mode: unpowered
IEC 60068-2-70
Part 2, Test Xb
Marking
The markings are rubbed with water for 10 cycles, then
with lubricating oil for 10 cycles.
Operating mode: unpowered
ISTA 2A 2001,
test categories 1,
4, 5, & 6
Package
In shipping packaging.
Cargo vibration and drop test.
Antenna
connectors
•
On all units:
•
Cellular SMA
•
SMA Diversity
•
On units with Wi-Fi option:
•
One RP SMA Wi-Fi
USB
Note: Do not use the USB port in a potentially explosive environment.
•
USB 2.0 Micro-AB connector complies with USB Version 2.0 for high
speed operation
•
Can be configured to operate in one of two modes:
•
Virtual Ethernet Port: The LX40 behaves as if the PC were
connected to an Ethernet port, allowing access to the Internet and the
LX40’s internal web server. This is the default setting.
•
Virtual Serial Port: The LX40 behaves as if it was connected to a
standard serial port. The primary use of this interface is for the AT
command line interface of ALEOS and for diagnostic access to the radio
module.
By default, the USB port is configured as a virtual Ethernet port.
•
A Windows driver must be installed on the PC in order to support USB
use. The drivers are available for download on Sierra Wireless’ support
web site:
source.sierrawireless.com/resources/airlink/software_downloads/
airlink_usb_driver/
•
The ALEOS Software Configuration User Guide contains the details of
USB mode configuration and driver installation.
•
Sierra Wireless recommends you:
•
Use a USB 2.0 cable
•
Connect directly to your computer for best throughput.
Ethernet
•
10/100/1000 Base-T RJ-45 Ethernet
•
Auto-crossover support
•
Auto-negotiation detects the speed of the connecting device
Test Method
Category
Description