FIREPLACE INSTALLATION-BUILD-IN
NEW CONSTRUCTION OR RENOVATION
CAUTION:
Two people may be needed to perform
this installation.
1. Select a location that is not prone to moisture
and is located at least 0.91 m or 3 feet away
from combustible materials such as curtains or
drapes, furniture, bedding, paper, etc.
Clearance to combustibles
Sides----------------------8 in / 20.3 cm
Floor-----------------------16 in / 40.6 cm
Top ------------------------2 in / 5 cm
Back ----------------------1/4 in / 0.6 cm
1. Place the appliance in selected location to
see how it will look in the future.
2. Mark the desired location on the floor and
store appliance in a safe, dry and dust free
location.
3. Prepare a wall with a framed opening to
accommodate the size of your unit. Please see
the table at the top of page 11 to determine the
rough wall opening size of the fireplace. Any
new wiring must be done in compliance with
local and national codes and other appliacable
regulations.
WARNING:
To prevent contact with sagging or loose
insulation, the electric appliance must not be
installed against vapor barrier or exposed
insulation. Overheating could occur and fire
may result.
WARNING:
Do not attempt to wire your own new outlets or
circuits. To reduce the risk of injury, electric
shock or fire, use a licensed electrician
local and national codes and other applicable