Repairs
2015-09-07 / DIS 113_58300000171499_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 58 of 65
6.18
Opening / closing refrigeration circuit
Graphic 23:Compressor: Refrigeration circuit
1
Tapping area (pressure side)
3
Area to be cut through (on pressure side)
2
Area to be cut through (on suction side)
Prerequisite:
•
Worktop has been removed.
•
Right side panel has been removed.
•
Drive belt has been removed.
•
Electrical connection of the compressor has been removed.
6.18.1
Opening the refrigeration circuit
1. Tap refrigeration circuit on the pressure side (1) using a piercing valve.
2. Extract and dispose of refrigerant as stipulated.
3. Disconnect compressor on the pressure side (3).
4. Disconnect compressor on the suction side (2).
5. Release hold points on the compressor and take compressor out of the
appliance.
6.18.2
Closing refrigeration circuit
Required tools:
?
Lokring
Prerequisite:
•
Compressor has been inserted.
► Seal circuit with a Lokring.