6 “Commissioning” menu
03.04.2006
•
Adding favorite pages and datapoints
•
Naming the favorite pages (titles)
•
Renaming the names of the datapoints
•
Sorting the favorite pages
•
Deleting datapoints and entire favorite pages
•
To improve readability, it is recommended to give the favorite pages self-explanatory
names
•
If individual devices are removed from the device list, the associated datapoints on
the favorite pages will also be removed
•
When deleting the entire device list, all favorite pages will be deleted also
6.4.1 Submenu
“Add
datapoints”
•
Creating favorite pages
•
Complementing favorite pages
•
Overwriting existing datapoints
Main menu > Commissioning > Favorite pages > Add datapoints
Operating line
Range
Factory setting
Favorites 1
Favorites 1
…
Favorites 20
Main menu > Commissioning > Favorite pages > Add datapoints > Favorites 1
to
Favorites 20
Operating line
Range
Factory setting
Datapoint name 1
…
…
Datapoint name 10
…
The favorite pages are presented with the title defined by the user. The factory setting
of the titles is
Favorites 1
…
Favorites 20
. Datapoints are presented with their names (copy
from the device menu tree). They can subsequently be renamed. Operating lines that
are not used appear as
…
.
Any datapoints from the menu trees of the devices on the device list can be assigned to
the favorite pages. The position – favorite page and line – can be freely selected. It is
also possible to overwrite existing datapoints by other datapoints. Subsequent sorting
of datapoints within the page is not possible.
Datapoints having a complex graphic display cannot be included in the favorites (time
switch, calendar, trend display, faults, etc.). Also, datapoints from the menus
Commis-
sioning
,
Favorites
,
Favorite pages
and
Device list
of the bus operator unit itself cannot be
included in the favorites either.
Operating mode
Add datapoints
is indicated by the
symbol in the corner at top right.
A datapoint is added according to the following procedure:
•
Select the respective favorite page (1…20)
•
Select the respective operating line (1…10)
•
Select the device from the device list
•
Navigate to the respective datapoint in the target device
•
Select the datapoint with the OK knob
•
Confirm adding with the OK knob and canceling with the ESC button
•
Return automatically to the selected favorite page (OK knob), or return to the se-
lected datapoint (ESC button)
Operating mode
Add datapoints
is quit under the following conditions (
symbol extin-
guishes):
Notes
Use
Operating lines