User programming via the keypad
6
User Menus
19
Siemens AB
A6V10209178
Security Products
26.09.2011
the size of their string.
If the Security Grade of the system is set to ’Unrestricted’, then the INHIBIT,
ISOLATE and GRANT ACCESS features may not be available in the user menu.
A Standard or Manager Type User profile is required to access the user
programming menus.
6.2.1
SYSTEM STATUS
The System Status feature displays all faults on the system.
To view these faults:
1. Scroll to SYSTEM STATUS.
2. Press SELECT.
A list of the alerts, isolations or open zones will be displayed.
The status of the battery and auxiliary power is also displayed.
6.2.2
ISOLATE
Zones, system alerts or alerts from X-BUS devices can be manually isolated from
the keypad. Isolating a zone removes that zone from the system until the user de-
isolates it.
To isolate zones, system alerts or alerts from X-BUS devices:
1. Scroll to ISOLATE and press SELECT.
2. Scroll to the desired option in the table below and press SELECT.
ZONE
Select the required zone and toggle the setting from NOT
ISOLATED to ISOLATED.
SYSTEM
Isolate the desired system alert.
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
XBUS COMMS LOST
XBUS FUSE FAULT (Expanders only)
X-BUS TAMPER
VIEW ISOLATIONS
To view a list of the isolated zones, system alerts and X-BUS
devices alerts.
6.2.3
INHIBIT
Zone and alerts from X-BUS devices can be manually inhibited from the keypad.
Inhibiting a zone removes that zone from the system for one alarm set period only.
To inhibit zones or alerts from X-BUS devices:
1. Scroll to INHIBIT and press SELECT.
2. Scroll to the desired option in the table below and press SELECT: