User programming via the keypad
6
User Menus
21
Siemens AB
A6V10209178
Security Products
26.09.2011
6.2.5
TEST
1. Scroll to TEST and press SELECT.
2. Scroll to the desired programming option.
6.2.5.1
BELL TEST
To perform a bell test:
Scroll to TEST > BELL TEST and press SELECT.
When BELL TEST is selected, the following options available: EXTERNAL
BELLS, STROBE, INTERNAL BELLS and BUZZER. When each of these
options is selected, the device sounds to verify it is operating correctly.
6.2.5.2
WALK TEST
A walk test ensures that the sensors are operating correctly on the SPC system.
To perform a walk test:
1. Scroll to TEST > WALK TEST.
2. Press SELECT.
3. The display indicates the number of zones to be tested on the system with the
text TO TEST XX (where XX is the number of valid walk test zones). Locate the
sensor on the first zone and activate it (open the door or window).
The keypad buzzer sounds continuously for approximately 2 seconds to
indicate that the zone activation has been detected and the number of
zones left to test (displayed on the keypad) decreases.
4. Continue with the remaining zones on the system until all zones have been
tested. If a zone activation does not get acknowledged by the system, check
the wiring of the sensor and/or replace with another sensor if necessary.
NOTICE
Only ALARM, ENTRY/EXIT and FIRE EXIT are valid zone types which are
included in a User walk test
6.2.5.3
WPA TEST
To perform a WPA test, the installer must have enrolled the WPA.
1. Scroll to TEST > WPA TEST.
2. Press SELECT.
The keypad display flashes ACTIVATE WPA.
3. Press and hold all 3 buttons on the WPA.
The LED on the WPA turns on.
The WPA transmitter ID, status and signal strength are displayed on the
keypad.