Variable
Note
Type
L
Rw
Default
Min.
Max.
Operating
time (minutes)
Total operating time of the
module (minutes)
UINT
2
r
0
-
-
Reserve 3
Reserve
REAL
4
r
0
-
-
8.14.1
Gross process weight
The current gross weight. Values are rounded as specified in data record DR 3 with
the "Decimal places for process values" (Page 64) parameter.
8.14.2
Net process weight
The current net weight. Values are rounded as specified in data record DR 3 with the "Decimal
places for process values" (Page 64) parameter.
8.14.3
Tare process weight
The current tare weight. Values are rounded as specified in data record DR 3 with the "Decimal
places for process values" (Page 64) parameter.
8.14.4
Gross / net weight
The current weight for the main display. The resolution corresponds to the scale interval
(Page 63) specified in data record DR 3.
8.14.5
Gross / net weight with increased resolution (x 10)
The current weight for the main display in higher resolution. The resolution corresponds to the
scale interval specified in data record DR 3 x 10.
8.14.6
Tare weight
The current tare weight (scale interval from DR 3). The resolution corresponds to the scale
interval specified in data record DR 3.
Scale parameters and functions
8.14 DR 30 current process values
SIWAREX WP321
86
Operating Instructions, 08/2019, A5E33715669A-AD