8BCOMMUNICATION WITH OTHER SYSTEMS
9.5 Data records for I/O communication
The data exchange via the I/O area takes place by means of parameters, commands, and
process values, which each possess their own data record number (mini data records - one
parameter - one data record). Here only a limited selection of data is available as per the
following table. Where channel-specific, the listed mini data records exist separately for each
channel.
DR
number
Meaning
Unit
Format
Default
Channel-
specific
Acces
s
Explanation
57
Commands
-
INT
0
y
w*
see DR11, 12 Commands
58 Scale
number
- CHAR
0
n
r/w
see DR5 Scale number
59
Port parameters
-
8 x BIT
0
n
r/w
see DR5 Port parameters
60
Adjustment digits0
Digits
WORD
0
y
r/w
see DR3, 4
61
Adjustment digits1
Digits
WORD
0
y
r/w
see DR3, 4
62
Adjustment weight
Weight INT
10000
y
r/w
see DR3, 4
63
LED assignment
Code
2 x Byte
101,10
2
n
r/w
see DR5 LED assignment
low byte K1; high byte K2
64
Zero set value
Digits
WORD
0
y
r/w
see DR3, 4
65
Char. value LC /
Filter setting /
Setting data
-
16x BOOL
0x0041
y
r/w
see DR3, 4
66
Limit value1 ON
Weight INT
10000
y
r/w
see DR21, 22
67
Limit value1 OFF
Weight INT
9990
y
r/w
see DR21, 22
68
Limit value2 ON
Weight INT
1000
y
r/w
see DR21, 22
69
Limit value2 OFF
Weight INT
1010
y
r/w
see DR21, 22
70
Default value1 for remote
display
- INT
0
n
r/w
see
DR6
71
Default value2 for remote
display
- INT
0
n
r/w
see
DR6
72
Display type
-
WORD
0
n
r/w
see DR5
(only low byte used)
73
Curr. digit value
Digits
WORD
-
y
r
see DR31, 32
0....65535
74
Gross
Weight INT
-
y
r
see DR21, 22
-32768..... +32767
75
Asynchronous errors
-
16 x BOOL
-
y
r
see DR31, 32
76
Synchronous errors
-
16 x BOOL
-
y
r
see DR31, 32
77 Version
- WORD
-
n
r see
DR40
78 Checksum
- UINT
-
n
r see
DR40
79
Component type
-
2 x BYTE
-
n
r
low byte: reserved
high byte: number of channels;
* r=read, w=write
Table 9-4
Data records for I/O communication
Note: In the case of channel-independent data records, where there is a two-
channel component data can be transferred for the first or second channel. If
values are transferred for both channels simultaneously (different), the value for
Channel 2 overwrites that of Channel 1.