3.2 Assembly
The conditions for installation are very different. The load platform can be very low or
relatively high. It could be a hopper, a platform or a conveyor for example. The following
assembly instructions can only be taken as general guidelines.
WARNING
Proper tools are to be used for lifting the load platform. Ensure that the respective
safety regulations are followed.
The load platform should always be built on dummies to begin with, so that the load cells
are protected from damages during assembly. The load platform must then only be lifted
a few millimeters from bracket to bracket to position the combination mounting unit. The
following description of assembly is based on this situation.
No. Designation
No. Designation
1 Base plate
10 Nut
2 Spacer bar
11 Overload protection
3 Load cell
12 Retaining ring
4 Washer
13 Oscillation housing
5 Hexagon head screw
14 Force guiding piece
6 Nut
15 Flat seal
7 Half-nut
16 Pendulum bolt
8 Washer
17 Force guiding piece
9 Countersunk screw
18 Top plate
Fig. 3-1 Structure of combination mounting unit