Service and maintenance
SITRANS WF100
34
Operating Instructions, 02/2012, 7ML19985NB01-01
Installing the shipping stop
CAUTION
When moving the unit reinstall the shipping stop to prevent damage to the load cell/sensing
plate assembly.
1.
With the sensing plate resting in its static position, insert shipping bolt as shown.
2.
Tighten the nut against the housing to secure the bolt in place.
1
2
3
4
5
①
Sensing plate
②
Washer
③
Shipping stop
④
Nut
⑤
SITRANS WF100 housing