Description
SITRANS WF100
Operating Instructions, 02/2012, 7ML19985NB01-01
11
Horizontal sensing plate
The material travels down the flowguide, striking the sensing plate and discharging through the
outlet. The force exerted on the sensing plate has both a vertical and horizontal component. The
design of the load cell is such that it reacts to the horizontal component only; the vertical
component is ignored.
The sensing plate is displaced proportionally to the material flow and is not susceptible to
material build-up, so long as it does not bridge across to the housing. Positive displacement of
the load cell is limited by the positive stop incorporated in the design of the load cell.
The displacement of the load cell is sensed by its strain gauges. These convert the excitation
signal from the electronic integrator to produce a signal proportional to material flow.
①
Positive stop
②
Negative stop
Summary of Contents for SITRANS WF100
Page 1: ...SITRANS Solid Flowmeters SITRANS WF100 Operating Instructions 02 2012 ...
Page 6: ...Table of contents SITRANS WF100 4 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 8: ...Introduction SITRANS WF100 6 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 26: ...Installing Mounting SITRANS WF100 24 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 28: ...Connecting SITRANS WF100 26 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 32: ...Commissioning SITRANS WF100 30 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 42: ...Technical data SITRANS WF100 40 Operating Instructions 02 2012 7ML19985NB01 01 ...
Page 44: ...Dimension drawings SITRANS WF100 42 Operating Instructions 02 2012 7ML19985NB01 01 ...